Xerox workcentre 5222 ошибка 116 334

System Cont detects [ESS-NVRAM with factory settings is installed] or [Illegal ESS-NVRAM

data is occurring].

Initial Actions

Power Off/On

Procedure

As powering OFF then ON after a detection of 116-334 will presumably cause other errors 124-3xx

that indicate various data mismatches between the three locations, resolve one(s) following the

corrective actions for the relevant Fault Code(s).

If 116-334 reoccurs despite powering OFF/ON, disconnect and reconnect the NV-RAM Board,

then turn ON the power.

If the problem persists, replace the NV-RAM Board.

If the problem still persists, replace the mercury battery.

Launch Version

WorkCentre 5225, 5230

116-335 HDD RAP

The control logic detected that the HDD failed.

Initial Actions

Power Off/On

Procedure

Check the HDD electrical connections

If the problem persists perform

If the problem persists replace the HDD

February, 2008

2-597

(PL

9.2).

Hard Disk Diagnostic

Program.

(PL

9.2).

116-334, 116-335

Status Indicator Raps

116-334 ESS NVRAM Data Compare Fail

116-334 ESS NVRAM data compare fail.

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

Perform the steps that follow:

1. Switch off, then switch on the machine, GP 10.
2. Enter dC125 Faults. If a 124-3XX fault code is also displayed, perform the relevant RAP.
3. Ensure that all connectors on the drive PWB, PL 1.10 Item 4 and the ESS PWB, PL 3.10 Item 6 are securely connected. Ensure all surface mounted modules on both PWBs are securely connected.
4. Reload the software, GP 4.
5. Perform the OF2 Special Boot Modes RAP.
6. If the fault persists, install a new ESS PWB, PL 3.10 Item 6.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

Прилепить пост

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑Из сервис мануала по WC M118 (конкретно на Ваш аппарат не нашел):
116-399
JME related critical error
Power OFF/ON, If continue, perform the following.
(1) Verify after updating ESS Firmware to the latest version.
(2) Reconnect and Replace RAM DIMM.
(3) Replace ESS PWB (PL 9.2).
(4) Collect the detail continue, perform the following.
a. Reinstall the ESS software.
b.Replace ESS PWB.

То есть советуют перетыкнуть и возможно заменить память, и плату на которой она сидит. Вам может понадобиться 101K55272

Аватар пользователя

service

Чихнул от тонера

  • Не в сети

Прилепить пост

Сообщение Aleks18131 » Вт окт 08, 2013 2:39 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑Ребят, может кто подскажет, какую группу контактов автоподатчика отключать?

Добавлено спустя 10 минут 32 секунды:
Xerox WC 5230 плата главная XEROX

service писал(а):Из сервис мануала по WC M118 (конкретно на Ваш аппарат не нашел):
116-399
JME related critical error
Power OFF/ON, If continue, perform the following.
(1) Verify after updating ESS Firmware to the latest version.
(2) Reconnect and Replace RAM DIMM.
(3) Replace ESS PWB (PL 9.2).
(4) Collect the detail continue, perform the following.
a. Reinstall the ESS software.
b.Replace ESS PWB.

То есть советуют перетыкнуть и возможно заменить память, и плату на которой она сидит. Вам может понадобиться 101K55272

заменил память с другого аппарата — выпала ошибка 116-389

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом


Прилепить пост

Сообщение Aleks18131 » Вт окт 08, 2013 2:54 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

service писал(а):И вообще интересная история: Вам под видом 540k08781 продали 540k08771, а в итоге нужен скорее всего 133k25440 :-) вроде ничего не перепутал

в итоге кстати 540k08781 встала и выдает ошибку 116-389 :-) она упихнулась в слот памяти — там на слоте был заусенец на защелке пластиковой, вот и не лезла :-) снял заусенец и встала как влитая. Теперь только вот эту ошибку победить осталось))

Добавлено спустя 15 минут 25 секунд:

Aleks18131 писал(а):

service писал(а):И вообще интересная история: Вам под видом 540k08781 продали 540k08771, а в итоге нужен скорее всего 133k25440 :-) вроде ничего не перепутал

в итоге кстати 540k08781 встала и выдает ошибку 116-389 :-) она упихнулась в слот памяти — там на слоте был заусенец на защелке пластиковой, вот и не лезла :-) снял заусенец и встала как влитая. Теперь только вот эту ошибку победить осталось))

в одном слоте 116-389, а в другом слоте 116-399.

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом

Прилепить пост

Сообщение service » Вт окт 08, 2013 3:10 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑С 116-389 примерно та же история:
Additional RAM not installed though necessary
Power OFF/ON, If continue, perform the following.
(1) Verify after updating ESS Firmware to the latest version.
(2) Reconnect and Replace RAM DIMM.
(3) Replace ESS PWB (PL 9.2).
(4) Collect the data

Похоже или недоткнули или не в ней все же дело. А не пробовали Verify after updating ESS Firmware to the latest version ?

Аватар пользователя

service

Чихнул от тонера

  • Не в сети

Прилепить пост

Сообщение Aleks18131 » Вт окт 08, 2013 3:17 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

service писал(а):С 116-389 примерно та же история:
Additional RAM not installed though necessary
Power OFF/ON, If continue, perform the following.
(1) Verify after updating ESS Firmware to the latest version.
(2) Reconnect and Replace RAM DIMM.
(3) Replace ESS PWB (PL 9.2).
(4) Collect the data

Похоже или недоткнули или не в ней все же дело. А не пробовали Verify after updating ESS Firmware to the latest version ?

нет :( А можно поподробнее как сделать Verify after updating ESS Firmware to the latest version?

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом


Прилепить пост

Сообщение Aleks18131 » Вт окт 08, 2013 4:03 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

service писал(а):Обновить прошивку до последней версии. Из руководства сисадмина:

ip аппарата неизвестен мне :(

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом


Прилепить пост

Сообщение dviz » Вт окт 08, 2013 4:56 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

Aleks18131 писал(а):Ребят, может кто подскажет, какую группу контактов автоподатчика отключать?

Все отключай.

116-399 — это ошибка при инициализации — причин судя по всему может быть несколько — память, прошивка, adf. Мне кажется проще всего отсоединить adf и посмотреть выйдет ли аппарат в готовность.

Вот из SM 5230:

116-399 Initialization RAP
Initialization exceeded 10 minutes.
Initial Actions
Power Off/On
Procedure
Reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 11.2).

116-389 RAM Install RAP
The control logic detected that the required RAM capacity is not installed or available.
Initial Actions
Power Off/On
Procedure
Reinstall or replace the DIMM (PL 9.2).
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 9.2).

Вот из SM 5230 картинка другая немножко(предыдущая была из партс листа с пометкой «February, 2008 — Launch Version», а эта — «June, 2008 — Revision (PDF)»), очень похожая на вашу плату. Обратите внимание, там указано какую память в какой слот пихать — очевидно если не туда воткнёшь, выдаст ошибку 116-389.

540K08780/540K08781 — Printer PWB
540K08771/540K08772 — PS DIMM
133K25440 — DDR DIMM (256MB)- 497K03680 — видимо то же самое
101K55270/101K55271/101K55272 — ESS PWB

Аватар пользователя

dviz

Блуждающий заряд

  • Не в сети
  • Персональный альбом

Прилепить пост

Сообщение Aleks18131 » Вт окт 08, 2013 9:32 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

dviz писал(а):

Aleks18131 писал(а):Ребят, может кто подскажет, какую группу контактов автоподатчика отключать?

Все отключай.

116-399 — это ошибка при инициализации — причин судя по всему может быть несколько — память, прошивка, adf. Мне кажется проще всего отсоединить adf и посмотреть выйдет ли аппарат в готовность.

Вот из SM 5230:

116-399 Initialization RAP
Initialization exceeded 10 minutes.
Initial Actions
Power Off/On
Procedure
Reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 11.2).

116-389 RAM Install RAP
The control logic detected that the required RAM capacity is not installed or available.
Initial Actions
Power Off/On
Procedure
Reinstall or replace the DIMM (PL 9.2).
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 9.2).

Вот из SM 5230 картинка другая немножко(предыдущая была из партс листа с пометкой «February, 2008 — Launch Version», а эта — «June, 2008 — Revision (PDF)»), очень похожая на вашу плату. Обратите внимание, там указано какую память в какой слот пихать — очевидно если не туда воткнёшь, выдаст ошибку 116-389.

540K08780/540K08781 — Printer PWB
540K08771/540K08772 — PS DIMM
133K25440 — DDR DIMM (256MB)- 497K03680 — видимо то же самое
101K55270/101K55271/101K55272 — ESS PWB

116-399 возникает если вставить в верхний (слот5 ). Если поставить в нижний (1), то 116-389, на 9 позицию она физически не встанет-разъем другой. Есть подозрение, что 399 возникла после того как батарейка сдохла и ее приходящий эникейщик решил поменять (выяснил таки что и в какой последовательности происходило: сперва не видел картридж — контактную площадку поправилили, ушел в отпуск — приходящий мальчик после «зависания аппарата и отказа выключаться» предложил свои услуги и открыв аппарат дернул батарейку. Девайс прожил ровно полчаса после этого и выпал в 399, после чего попросили меня посмотреть не возможно ли что-то сделать :-) ). Вот теперь я и вытворяю танцы с бубном у аппарата crazy

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом



Прилепить пост

Сообщение Aleks18131 » Пн окт 14, 2013 11:04 am

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

dviz писал(а):Читали в SM процедуру обновления ПО?

перечитал мануал. Указанно, что можно выставить ip вручную, а можно по DHCP либо можно распечатать. Только он же не проходит инициализацию, а после попытки прогрузить выпадает в ошибку. Процедура обновления:
1. Убедитесь, что аппарат включен, работает и не находится в режиме
экономии энергии.
2. Откройте веб-браузер и введите IP-адрес аппарата в поле [Адрес] или
[Местоположение], затем нажмите [Ввод].
3. Перейдите на вкладку [Свойства].
4. Щелкните папку [Режимы].
5. Щелкните папку [Программное обеспечение аппарата].
6. В папке [Программное обеспечение аппарата]
1. Щелкните [Обновления]. Установите флажок [Включено] и щелкните
[Применить].
2. Щелкните [Обновление вручную]. Нажмите [Обзор] и перейдите к новому
программному обеспечению в файловой системе. Чтобы установить
программное обеспечение, щелкните [Установить программного
обеспечения].
ПРИМЕЧАНИЕ. Переход от пункта [Обновления] к пункту [Обновление вручную]
позволит провести обновление программного обеспечения вручную.

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом

Прилепить пост

Сообщение Aleks18131 » Пн окт 14, 2013 11:37 am

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑вернее ip то он типа как назначает — однако ж операционка ругается в сетях, что типа как не был назначен сетевой адрес. Если же попробовать перейти по тому, который указан в подробностях-браузер ругается на недействительный адрес :(

Добавлено спустя 7 часов 7 минут 12 секунд:
Xerox WC 5230 плата главная XEROX
и кстати говоря — как же это вы мне предлагаете обновить ПО, если 116-399 возникает только при отказе инициализироваться?

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом


  • Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»

    kotya-potya в форуме Принтеры, МФУ, факсы, копиры формата A4

    5
    5299

    3100
    Перейти к последнему сообщению
    Пн ноя 18, 2019 8:24 pm
  • Xerox WC 3119: «Замятие 1»

    kokubenko в форуме Принтеры, МФУ, факсы, копиры формата A4

    22
    38583

    kokubenko
    Перейти к последнему сообщению
    Ср ноя 23, 2011 4:47 pm
  • Xerox WC3220 — Ложное замятие бумаги, Замятие 0

    Romeo в форуме Принтеры, МФУ, факсы, копиры формата A4

    25
    10112

    Romeo
    Перейти к последнему сообщению
    Пн окт 12, 2020 7:13 pm
  • Xerox 3315 «слетела» FIX прошивка

    tekknik в форуме Принтеры, МФУ, факсы, копиры формата A4

    7
    6834

    tekknik
    Перейти к последнему сообщению
    Пн июн 10, 2019 4:22 am
  • Xerox 3428 «Установите Картридж»

    Roller-ch в форуме Принтеры, МФУ, факсы, копиры формата A4

    6
    9317

    SeMi
    Перейти к последнему сообщению
    Сб авг 27, 2011 6:42 pm

Вернуться в Принтеры, МФУ, копиры формата A3

Кто сейчас на форуме

Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 17

  1. 10-07-2015

    #1

    jmandassociates is offline


    Senior Tech

    100+ Posts


    Rep Power
    31

    Xerox Color 570 errors 116-334 and 116-312

    Working on 2 Xerox Color 570 we just got in both with problems. Previous owner kept the hard drives. We replaced them with 80GB sata hard drives we had laying around. Not sure if they need to be Xerox specific and that could be part of the problem.

    The first machine the first time you power it on it will get to step 2/6 in the initial loading process and then an error message �please reboot 116-334� pops up. I reboot and no longer got this error but it freezes on step 2/6 of loading process. It will stay stuck on this screen until you restart the copier, but will freeze on this same 2/6 screen every time after that (no more �please reboot 116-334� error). If you totally unplug the copier and try to start it again, you will get the �please reboot 116-334� error message again, only the first time, and then will freeze on 2/6 every other time you restart the copier.

    The second machine loads to fault/error screen with code: 116-312 every time

    Any help would be greatly appreciated.


  2. 10-07-2015

    #2

    Jake2o is offline


    Senior Tech

    250+ Posts

    Jake2o's Avatar


    Rep Power
    34

    Re: Xerox Color 570 errors 116-334 and 116-312

    Quote Originally Posted by jmandassociates
    View Post

    Working on 2 Xerox Color 570 we just got in both with problems. Previous owner kept the hard drives. We replaced them with 80GB sata hard drives we had laying around. Not sure if they need to be Xerox specific and that could be part of the problem.

    The first machine the first time you power it on it will get to step 2/6 in the initial loading process and then an error message �please reboot 116-334� pops up. I reboot and no longer got this error but it freezes on step 2/6 of loading process. It will stay stuck on this screen until you restart the copier, but will freeze on this same 2/6 screen every time after that (no more �please reboot 116-334� error). If you totally unplug the copier and try to start it again, you will get the �please reboot 116-334� error message again, only the first time, and then will freeze on 2/6 every other time you restart the copier.

    The second machine loads to fault/error screen with code: 116-312 every time

    Any help would be greatly appreciated.

    Machine 2 for certain thhis is what the error code means
    An error was detected in the HDD encryption key during activation.Procedure

    • Switch the power Off, then On. If the problem still exists, perform the following:
    • Refer to the Initialize Hard Disk Procedure in UI Diagnostics. Listed below
    • If the problem still exists, replace the HDD ( PL 11.6).
    • When the system has been recovered, set the HDD encryption key.

    This routine initializes Partition A of the HDD. Partition A contains the following data: added fonts, forms for ART EX, ART IV (optional), PC-PR201H, ESC/P, and HP-GL/2 (optional), ART IV User Defined Data, and SMB folder.

    Initialization Procedure
    Enter UI Diagnostic mode (see Accessing UI Diagnostics). Select Initialize Hard Disk. The Partition A radio button appears.
    Select Partition A then select Start.
    A confirmation message appears. Select Yes.
    A message indicating the completion appears. Select Confirm.
    This completes the initialization of Partition A.

    Still working on the first machine error code i don’t have it in the manual.


  1. 10-07-2015


    #1

    jmandassociates is offline


    Senior Tech

    100+ Posts


    Rep Power
    31

    Xerox Color 570 errors 116-334 and 116-312

    Working on 2 Xerox Color 570 we just got in both with problems. Previous owner kept the hard drives. We replaced them with 80GB sata hard drives we had laying around. Not sure if they need to be Xerox specific and that could be part of the problem.

    The first machine the first time you power it on it will get to step 2/6 in the initial loading process and then an error message �please reboot 116-334� pops up. I reboot and no longer got this error but it freezes on step 2/6 of loading process. It will stay stuck on this screen until you restart the copier, but will freeze on this same 2/6 screen every time after that (no more �please reboot 116-334� error). If you totally unplug the copier and try to start it again, you will get the �please reboot 116-334� error message again, only the first time, and then will freeze on 2/6 every other time you restart the copier.

    The second machine loads to fault/error screen with code: 116-312 every time

    Any help would be greatly appreciated.


  2. 10-07-2015


    #2

    Jake2o is offline


    Senior Tech

    250+ Posts

    Jake2o's Avatar


    Rep Power
    35

    Re: Xerox Color 570 errors 116-334 and 116-312

    Quote Originally Posted by jmandassociates
    View Post

    Working on 2 Xerox Color 570 we just got in both with problems. Previous owner kept the hard drives. We replaced them with 80GB sata hard drives we had laying around. Not sure if they need to be Xerox specific and that could be part of the problem.

    The first machine the first time you power it on it will get to step 2/6 in the initial loading process and then an error message �please reboot 116-334� pops up. I reboot and no longer got this error but it freezes on step 2/6 of loading process. It will stay stuck on this screen until you restart the copier, but will freeze on this same 2/6 screen every time after that (no more �please reboot 116-334� error). If you totally unplug the copier and try to start it again, you will get the �please reboot 116-334� error message again, only the first time, and then will freeze on 2/6 every other time you restart the copier.

    The second machine loads to fault/error screen with code: 116-312 every time

    Any help would be greatly appreciated.

    Machine 2 for certain thhis is what the error code means
    An error was detected in the HDD encryption key during activation.Procedure

    • Switch the power Off, then On. If the problem still exists, perform the following:
    • Refer to the Initialize Hard Disk Procedure in UI Diagnostics. Listed below
    • If the problem still exists, replace the HDD ( PL 11.6).
    • When the system has been recovered, set the HDD encryption key.

    This routine initializes Partition A of the HDD. Partition A contains the following data: added fonts, forms for ART EX, ART IV (optional), PC-PR201H, ESC/P, and HP-GL/2 (optional), ART IV User Defined Data, and SMB folder.

    Initialization Procedure
    Enter UI Diagnostic mode (see Accessing UI Diagnostics). Select Initialize Hard Disk. The Partition A radio button appears.
    Select Partition A then select Start.
    A confirmation message appears. Select Yes.
    A message indicating the completion appears. Select Confirm.
    This completes the initialization of Partition A.

    Still working on the first machine error code i don’t have it in the manual.


  • 14 Май 2015

Приветствую всех . Есть 3 аппарата Xerox WC 5222 но 1 начал выдавать Ошибка 116-324 . По поиску в интернете нашёл что виновата оперативная память . Поменял их местами с заведомо рабочего аппарата и нерабочего , толку ноль … Но есть ещё 1 нюанс если его выдернуть из сети то он запускается и работает без ошибки — копирует всё нормально . Как только его подключаешь в сеть сразу выдаёт ошибку — «Сохранение данных » и с низу ошибка 116-324 .
На плате стоит жесткий диск и ещё 1 платка с энерго независимой памятью 24С02.
Как я понял в платке 24с02 хранятся лицензионные ключи и какие то настройки . в жестком диске ПО , Не могу понять что глючит в этом аппарате . :help:
Или дайте кто нибудь сервисный мануал на xerox WC 5222/25/30 на почту.

Только что прогнал жёсткий диск через викторию всё нормально :(

  • 14 Май 2015

Только что прогнал жёсткий диск через викторию всё нормально
а сколько на нем места свободного?

  • 14 Май 2015

kostya666, На компьютере разделы не определились , проверял жесткий диск Викторией на битые сектора …
Можно как то через веб интерфейс посмотреть в аппарате сколько места в нём ?

  • 14 Май 2015

SisDan сказал(а):

Можно как то через веб интерфейс посмотреть в аппарате сколько места в нём ?

думаю да. проверь сколько там свободно.

SisDan сказал(а):

о есть ещё 1 нюанс если его выдернуть из сети то он запускается и работает без ошибки — копирует всё нормально . Как только его подключаешь в сеть сразу выдаёт ошибку — «Сохранение данных » и с низу ошибка 116-324 .

может конфликтует с сеткой?

  • 14 Май 2015

kostya666, Проверил жесткий — он пустой полностью — проверял через Acronis .

После смены настроек на DHCP сервере и смены IP адреса на назначение принтеру -(Поставил другой ИП на аппарате) Он включился вместе с сеткой ! Значит что то не то шло с какого то компа который был завязан на него !
Найду причину отпишусь .

Добавлено 14-05-2015 14:52

kostya666, У меня вот такой вопрос разница между прошивками какая — v1.207.8 PS Firmware and Installation Instructions и v1.207.8 STD firmware and Installation Instructions
Чем они отличаются ? Просто хочу перепрошить аппарат на всякий случай :p

  • 14 Май 2015

SisDan, не мучай исправный аппарат, он скорее всего завязан на принтсервер, потому без него и выскакивает ошибка. Перенастроить как нужно клиенту, взять за это денег и никуда не лазить, пока не убил в нём что-нибудь, прошивальщик хренов. :gigi:

  • 14 Май 2015

Генчик, С техникой давно общаюсь , и именно этот аппарат уже не первый раз выкобенивается … 2 остальных работают без проблем . Да и аппарат разобран :gigi: денег взять не получится я зарплату за ремонт техники получаю :cry:
принт сервер у него встроенный .
Да и сам аппарат авторизуется в актив директории в доменной сети .

  • 14 Май 2015

SisDan, ты объясни толком, аппараты в твоей конторе стоят? Сисадмин есть? Ну явно же не железная проблема.

  • 14 Май 2015

Генчик, Да аппараты стоят у нас на в конторе и я их обслуживаю . Просто не понятно почему глючит 1 аппарат . Все аппараты проработали 4,5 года последний год глючит только 1 , чистку и ТО делал , В скором времени запланирована замена печки .

Я уже писал по другой ошибки но там проблема была в шлейфе автоподатчика — заменил на который я сам своял из стах принтеров и проблема исчезла .

  • 14 Май 2015

SisDan, Не надо ни чего прошивать, настрой сетку нормально и забудь!
Аппарат исправный, конфликт по IP скорее всего!

  • 14 Май 2015

kostya666, Раздачей IP занимается СЕРВАК у нас DHCP — динамические IP Адреса .
С сеткой всё нормально .

  • 14 Май 2015

SisDan сказал(а):

принт сервер у него встроенный .

SisDan, нет там никакого принт-сервера, просто обычный сетевой принтер оффисного уровня. :gigi:

SisDan сказал(а):

Да и сам аппарат авторизуется в актив директории в доменной сети .

SisDan, вот об этом я тебе и говорю, что проблема не в самом аппарате, а в настройках доменного принт-сервера. Если ты поменяешь местами этот аппарат с таким-же из двух других, естественно поменяв соответствущие настройки, то 99% начнёт глючить другой, а этот будет преспокойно работать в другом месте.

Добавлено 14.05.2015 13:25

SisDan сказал(а):

Вот это весьма сомнительно. :gigi:
SisDan, если ты сам там сисадмин, то бегом учить системную матчасть. :gigi: Если сисадмин кто-то другой, то нагнуть его проверить все настройки принтсервера для этого аппарата.
А вообще гнать его метлой из сисадминов за динамический IP для сетевых принтеров. :gigi: Большей глупости придумать невозможно. :gigi:

  • 14 Май 2015

Генчик, начнём по порядку , 1. DHCP сервак по мак адресу назначает IP Адрес принтеру По зарезервированным адресам для принтеров .
2. Пользователь отсылает на печать на IP Адрес принтера — Напрямую минуя сервак .
3. Если нужно от сканировать это делается с самого Аппарата по настроенному шаблону — И только по шаблону принтер авторизуется в актив директории и отсылает обратно .

Добавлено 14-05-2015 15:30

Ошибка 116-324

15.03.2013

Модель: Xerox WorkCentre 5225

Здравствуйте, выходит ошибка 116-324, но только когда мфу подключен к сети? Что делать?

Ответ:

Данная ошибка означает, что возникли проблемы с оперативной памятью аппарата, т.е. вам нужно заменить плату RAMDIM.

Добавлено 14-05-2015 15:31

Это ответ Альфатех

  • 14 Май 2015

SisDan сказал(а):

1. DHCP сервак по мак адресу назначает IP Адрес принтеру По зарезервированным адресам для принтеров .

SisDan, это правильно. Ещё правильнее делать так и для всех сетевых девайсов, включая компы.

SisDan сказал(а):

2. Пользователь отсылает на печать на IP Адрес принтера — Напрямую минуя сервак .

SisDan, куйня полная! Никакого контроля и возможности админу вмешаться в процесс печати. Если какой-нибудь дебил захочет завалить аппарат заданиями на печать, у него есть все возможности для этого. :gigi:

SisDan сказал(а):

3. Если нужно от сканировать это делается с самого Аппарата по настроенному шаблону — И только по шаблону принтер авторизуется в актив директории и отсылает обратно .

SisDan, ну хоть что-то сделали правильно. :gigi:

SisDan сказал(а):

Данная ошибка означает, что возникли проблемы с оперативной памятью аппарата, т.е. вам нужно заменить плату RAMDIM.

SisDan, куйня полная! Какой-то дебил юзверь гонит на печать немерянное количество куйни, а из-за отсутствия принтсервера и очереди печать на нём, происходит переполнение буфера аппарата. Сконфигурировать правильно принт-сервер в домене и забыть об этой ошибке. :gigi:

  • 14 Май 2015

Генчик, Аппарат стоит прямо в кабинете в отделе у пользователей ! Пусть заваливает спрос с пользователя будет . Расходные материалы ограничены на каждый отдел ) Переборщили или сломали — сидят без принтера . :gigi:

Добавлено 14-05-2015 15:43

Генчик, Сервак перенастроил пока ни кто не отсылает на печать он в сети работает … Пойду перенастрою пользователей и посмотрю на каком именно он встанет в ошибку . По результатам отпишусь .

  • 14 Май 2015

SisDan сказал(а):

Аппарат стоит прямо в кабинете в отделе у пользователей ! Пусть заваливает спрос с пользователя будет .

SisDan, балбес, они уже завалили, а ипёшся ты. и спрос тоже с тебя. :lol:

  • 14 Май 2015

Прикольно, у меня знакомые админы на такую технику ставят фиксированные адреса, а не динамические.
В драйвере прописывают принтер/МФУ и работают.
А то питание выключишь, включишь и ищи своё устройство… :gigi:

  • 14 Май 2015

Владимир Анатольевич сказал(а):

у меня знакомые админы на такую технику ставят фиксированные адреса, а не динамические.

Владимир Анатольевич, а там и получается фиксированный адрес, поскольку в AD (домене) прописывается фиксированный IP для определённого MAC. Ты бы не лез обсуждать то, в чём ни хрена не понимаешь. :gigi:

  • 15 Май 2015

Генчик, Посмотрел ЛОГ принтера с утра и Логе весели ошибки — 026-714 proxy — Склонирова с рабочего аппарата настройки на него и подправил шаблоны под их отдел — пол дня отработали больше ошибок не было :mrgreen:
Всем Спасибо за помощь .

Добавлено 15-05-2015 12:45

Генчик, Спасибо за подсказку по настройке — буду читать по настройке принт сервиса на 2008 серваке и попробую поднять сначала на виртуальной машине :gigi: а потом на нашем сераваке попробую !

Тему можно считать закрытой .

116-334 ESS NVRAM Data Compare Fail

116-334 ESS NVRAM data compare fail.

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

Perform the steps that follow:

1. Switch off, then switch on the machine, GP 10.
2. Enter dC125 Faults. If a 124-3XX fault code is also displayed, perform the relevant RAP.
3. Ensure that all connectors on the drive PWB, PL 1.10 Item 4 and the ESS PWB, PL 3.10 Item 6 are securely connected. Ensure all surface mounted modules on both PWBs are securely connected.
4. Reload the software, GP 4.
5. Perform the OF2 Special Boot Modes RAP.
6. If the fault persists, install a new ESS PWB, PL 3.10 Item 6.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

System Cont detects [ESS-NVRAM with factory settings is installed] or [Illegal ESS-NVRAM

data is occurring].

Initial Actions

Power Off/On

Procedure

As powering OFF then ON after a detection of 116-334 will presumably cause other errors 124-3xx

that indicate various data mismatches between the three locations, resolve one(s) following the

corrective actions for the relevant Fault Code(s).

If 116-334 reoccurs despite powering OFF/ON, disconnect and reconnect the NV-RAM Board,

then turn ON the power.

If the problem persists, replace the NV-RAM Board.

If the problem still persists, replace the mercury battery.

Launch Version

WorkCentre 5225, 5230

116-335 HDD RAP

The control logic detected that the HDD failed.

Initial Actions

Power Off/On

Procedure

Check the HDD electrical connections

If the problem persists perform

If the problem persists replace the HDD

February, 2008

2-597

(PL

9.2).

Hard Disk Diagnostic

Program.

(PL

9.2).

116-334, 116-335

Status Indicator Raps

116-334 ESS NVRAM Data Compare Fail

116-334 ESS NVRAM data compare fail.

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

Perform the steps that follow:

1. Switch off, then switch on the machine, GP 10.
2. Enter dC125 Faults. If a 124-3XX fault code is also displayed, perform the relevant RAP.
3. Ensure that all connectors on the drive PWB, PL 1.10 Item 4 and the ESS PWB, PL 3.10 Item 6 are securely connected. Ensure all surface mounted modules on both PWBs are securely connected.
4. Reload the software, GP 4.
5. Perform the OF2 Special Boot Modes RAP.
6. If the fault persists, install a new ESS PWB, PL 3.10 Item 6.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

Прилепить пост

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑Из сервис мануала по WC M118 (конкретно на Ваш аппарат не нашел):
116-399
JME related critical error
Power OFF/ON, If continue, perform the following.
(1) Verify after updating ESS Firmware to the latest version.
(2) Reconnect and Replace RAM DIMM.
(3) Replace ESS PWB (PL 9.2).
(4) Collect the detail continue, perform the following.
a. Reinstall the ESS software.
b.Replace ESS PWB.

То есть советуют перетыкнуть и возможно заменить память, и плату на которой она сидит. Вам может понадобиться 101K55272

Аватар пользователя

service

Чихнул от тонера

  • Не в сети

Прилепить пост

Сообщение Aleks18131 » Вт окт 08, 2013 2:39 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑Ребят, может кто подскажет, какую группу контактов автоподатчика отключать?

Добавлено спустя 10 минут 32 секунды:
Xerox WC 5230 плата главная XEROX

service писал(а):Из сервис мануала по WC M118 (конкретно на Ваш аппарат не нашел):
116-399
JME related critical error
Power OFF/ON, If continue, perform the following.
(1) Verify after updating ESS Firmware to the latest version.
(2) Reconnect and Replace RAM DIMM.
(3) Replace ESS PWB (PL 9.2).
(4) Collect the detail continue, perform the following.
a. Reinstall the ESS software.
b.Replace ESS PWB.

То есть советуют перетыкнуть и возможно заменить память, и плату на которой она сидит. Вам может понадобиться 101K55272

заменил память с другого аппарата — выпала ошибка 116-389

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом


Прилепить пост

Сообщение Aleks18131 » Вт окт 08, 2013 2:54 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

service писал(а):И вообще интересная история: Вам под видом 540k08781 продали 540k08771, а в итоге нужен скорее всего 133k25440 :-) вроде ничего не перепутал

в итоге кстати 540k08781 встала и выдает ошибку 116-389 :-) она упихнулась в слот памяти — там на слоте был заусенец на защелке пластиковой, вот и не лезла :-) снял заусенец и встала как влитая. Теперь только вот эту ошибку победить осталось))

Добавлено спустя 15 минут 25 секунд:

Aleks18131 писал(а):

service писал(а):И вообще интересная история: Вам под видом 540k08781 продали 540k08771, а в итоге нужен скорее всего 133k25440 :-) вроде ничего не перепутал

в итоге кстати 540k08781 встала и выдает ошибку 116-389 :-) она упихнулась в слот памяти — там на слоте был заусенец на защелке пластиковой, вот и не лезла :-) снял заусенец и встала как влитая. Теперь только вот эту ошибку победить осталось))

в одном слоте 116-389, а в другом слоте 116-399.

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом

Прилепить пост

Сообщение service » Вт окт 08, 2013 3:10 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑С 116-389 примерно та же история:
Additional RAM not installed though necessary
Power OFF/ON, If continue, perform the following.
(1) Verify after updating ESS Firmware to the latest version.
(2) Reconnect and Replace RAM DIMM.
(3) Replace ESS PWB (PL 9.2).
(4) Collect the data

Похоже или недоткнули или не в ней все же дело. А не пробовали Verify after updating ESS Firmware to the latest version ?

Аватар пользователя

service

Чихнул от тонера

  • Не в сети

Прилепить пост

Сообщение Aleks18131 » Вт окт 08, 2013 3:17 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

service писал(а):С 116-389 примерно та же история:
Additional RAM not installed though necessary
Power OFF/ON, If continue, perform the following.
(1) Verify after updating ESS Firmware to the latest version.
(2) Reconnect and Replace RAM DIMM.
(3) Replace ESS PWB (PL 9.2).
(4) Collect the data

Похоже или недоткнули или не в ней все же дело. А не пробовали Verify after updating ESS Firmware to the latest version ?

нет А можно поподробнее как сделать Verify after updating ESS Firmware to the latest version?

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом


Прилепить пост

Сообщение Aleks18131 » Вт окт 08, 2013 4:03 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

service писал(а):Обновить прошивку до последней версии. Из руководства сисадмина:

ip аппарата неизвестен мне

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом


Прилепить пост

Сообщение dviz » Вт окт 08, 2013 4:56 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

Aleks18131 писал(а):Ребят, может кто подскажет, какую группу контактов автоподатчика отключать?

Все отключай.

116-399 — это ошибка при инициализации — причин судя по всему может быть несколько — память, прошивка, adf. Мне кажется проще всего отсоединить adf и посмотреть выйдет ли аппарат в готовность.

Вот из SM 5230:

116-399 Initialization RAP
Initialization exceeded 10 minutes.
Initial Actions
Power Off/On
Procedure
Reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 11.2).

116-389 RAM Install RAP
The control logic detected that the required RAM capacity is not installed or available.
Initial Actions
Power Off/On
Procedure
Reinstall or replace the DIMM (PL 9.2).
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 9.2).

Вот из SM 5230 картинка другая немножко(предыдущая была из партс листа с пометкой «February, 2008 — Launch Version», а эта — «June, 2008 — Revision (PDF)»), очень похожая на вашу плату. Обратите внимание, там указано какую память в какой слот пихать — очевидно если не туда воткнёшь, выдаст ошибку 116-389.

540K08780/540K08781 — Printer PWB
540K08771/540K08772 — PS DIMM
133K25440 — DDR DIMM (256MB)- 497K03680 — видимо то же самое
101K55270/101K55271/101K55272 — ESS PWB

Аватар пользователя

dviz

Блуждающий заряд

  • Не в сети
  • Персональный альбом

Прилепить пост

Сообщение Aleks18131 » Вт окт 08, 2013 9:32 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

dviz писал(а):

Aleks18131 писал(а):Ребят, может кто подскажет, какую группу контактов автоподатчика отключать?

Все отключай.

116-399 — это ошибка при инициализации — причин судя по всему может быть несколько — память, прошивка, adf. Мне кажется проще всего отсоединить adf и посмотреть выйдет ли аппарат в готовность.

Вот из SM 5230:

116-399 Initialization RAP
Initialization exceeded 10 minutes.
Initial Actions
Power Off/On
Procedure
Reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 11.2).

116-389 RAM Install RAP
The control logic detected that the required RAM capacity is not installed or available.
Initial Actions
Power Off/On
Procedure
Reinstall or replace the DIMM (PL 9.2).
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 9.2).

Вот из SM 5230 картинка другая немножко(предыдущая была из партс листа с пометкой «February, 2008 — Launch Version», а эта — «June, 2008 — Revision (PDF)»), очень похожая на вашу плату. Обратите внимание, там указано какую память в какой слот пихать — очевидно если не туда воткнёшь, выдаст ошибку 116-389.

540K08780/540K08781 — Printer PWB
540K08771/540K08772 — PS DIMM
133K25440 — DDR DIMM (256MB)- 497K03680 — видимо то же самое
101K55270/101K55271/101K55272 — ESS PWB

116-399 возникает если вставить в верхний (слот5 ). Если поставить в нижний (1), то 116-389, на 9 позицию она физически не встанет-разъем другой. Есть подозрение, что 399 возникла после того как батарейка сдохла и ее приходящий эникейщик решил поменять (выяснил таки что и в какой последовательности происходило: сперва не видел картридж — контактную площадку поправилили, ушел в отпуск — приходящий мальчик после «зависания аппарата и отказа выключаться» предложил свои услуги и открыв аппарат дернул батарейку. Девайс прожил ровно полчаса после этого и выпал в 399, после чего попросили меня посмотреть не возможно ли что-то сделать :-) ). Вот теперь я и вытворяю танцы с бубном у аппарата crazy

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом



Прилепить пост

Сообщение Aleks18131 » Пн окт 14, 2013 11:04 am

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

dviz писал(а):Читали в SM процедуру обновления ПО?

перечитал мануал. Указанно, что можно выставить ip вручную, а можно по DHCP либо можно распечатать. Только он же не проходит инициализацию, а после попытки прогрузить выпадает в ошибку. Процедура обновления:
1. Убедитесь, что аппарат включен, работает и не находится в режиме
экономии энергии.
2. Откройте веб-браузер и введите IP-адрес аппарата в поле [Адрес] или
[Местоположение], затем нажмите [Ввод].
3. Перейдите на вкладку [Свойства].
4. Щелкните папку [Режимы].
5. Щелкните папку [Программное обеспечение аппарата].
6. В папке [Программное обеспечение аппарата]
1. Щелкните [Обновления]. Установите флажок [Включено] и щелкните
[Применить].
2. Щелкните [Обновление вручную]. Нажмите [Обзор] и перейдите к новому
программному обеспечению в файловой системе. Чтобы установить
программное обеспечение, щелкните [Установить программного
обеспечения].
ПРИМЕЧАНИЕ. Переход от пункта [Обновления] к пункту [Обновление вручную]
позволит провести обновление программного обеспечения вручную.

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом

Прилепить пост

Сообщение Aleks18131 » Пн окт 14, 2013 11:37 am

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑вернее ip то он типа как назначает — однако ж операционка ругается в сетях, что типа как не был назначен сетевой адрес. Если же попробовать перейти по тому, который указан в подробностях-браузер ругается на недействительный адрес

Добавлено спустя 7 часов 7 минут 12 секунд:
Xerox WC 5230 плата главная XEROX
и кстати говоря — как же это вы мне предлагаете обновить ПО, если 116-399 возникает только при отказе инициализироваться?

Аватар пользователя

Aleks18131

Подошел к чернилам

  • Не в сети
  • Персональный альбом


  • Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»

    kotya-potya в форуме Принтеры, МФУ, факсы, копиры формата A4

    5
    5299

    3100
    Перейти к последнему сообщению
    Пн ноя 18, 2019 8:24 pm
  • Xerox WC 3119: «Замятие 1»

    kokubenko в форуме Принтеры, МФУ, факсы, копиры формата A4

    22
    38583

    kokubenko
    Перейти к последнему сообщению
    Ср ноя 23, 2011 4:47 pm
  • Xerox WC3220 — Ложное замятие бумаги, Замятие 0

    Romeo в форуме Принтеры, МФУ, факсы, копиры формата A4

    25
    10112

    Romeo
    Перейти к последнему сообщению
    Пн окт 12, 2020 7:13 pm
  • Xerox 3315 «слетела» FIX прошивка

    tekknik в форуме Принтеры, МФУ, факсы, копиры формата A4

    7
    6834

    tekknik
    Перейти к последнему сообщению
    Пн июн 10, 2019 4:22 am
  • Xerox 3428 «Установите Картридж»

    Roller-ch в форуме Принтеры, МФУ, факсы, копиры формата A4

    6
    9317

    SeMi
    Перейти к последнему сообщению
    Сб авг 27, 2011 6:42 pm

Вернуться в Принтеры, МФУ, копиры формата A3

Кто сейчас на форуме

Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 17

  1. 10-07-2015

    #1

    jmandassociates is offline


    Senior Tech

    100+ Posts


    Rep Power
    31

    Xerox Color 570 errors 116-334 and 116-312

    Working on 2 Xerox Color 570 we just got in both with problems. Previous owner kept the hard drives. We replaced them with 80GB sata hard drives we had laying around. Not sure if they need to be Xerox specific and that could be part of the problem.

    The first machine the first time you power it on it will get to step 2/6 in the initial loading process and then an error message �please reboot 116-334� pops up. I reboot and no longer got this error but it freezes on step 2/6 of loading process. It will stay stuck on this screen until you restart the copier, but will freeze on this same 2/6 screen every time after that (no more �please reboot 116-334� error). If you totally unplug the copier and try to start it again, you will get the �please reboot 116-334� error message again, only the first time, and then will freeze on 2/6 every other time you restart the copier.

    The second machine loads to fault/error screen with code: 116-312 every time

    Any help would be greatly appreciated.


  2. 10-07-2015

    #2

    Jake2o is offline


    Senior Tech

    250+ Posts

    Jake2o's Avatar


    Rep Power
    34

    Re: Xerox Color 570 errors 116-334 and 116-312

    Quote Originally Posted by jmandassociates
    View Post

    Working on 2 Xerox Color 570 we just got in both with problems. Previous owner kept the hard drives. We replaced them with 80GB sata hard drives we had laying around. Not sure if they need to be Xerox specific and that could be part of the problem.

    The first machine the first time you power it on it will get to step 2/6 in the initial loading process and then an error message �please reboot 116-334� pops up. I reboot and no longer got this error but it freezes on step 2/6 of loading process. It will stay stuck on this screen until you restart the copier, but will freeze on this same 2/6 screen every time after that (no more �please reboot 116-334� error). If you totally unplug the copier and try to start it again, you will get the �please reboot 116-334� error message again, only the first time, and then will freeze on 2/6 every other time you restart the copier.

    The second machine loads to fault/error screen with code: 116-312 every time

    Any help would be greatly appreciated.

    Machine 2 for certain thhis is what the error code means
    An error was detected in the HDD encryption key during activation.Procedure

    • Switch the power Off, then On. If the problem still exists, perform the following:
    • Refer to the Initialize Hard Disk Procedure in UI Diagnostics. Listed below
    • If the problem still exists, replace the HDD ( PL 11.6).
    • When the system has been recovered, set the HDD encryption key.

    This routine initializes Partition A of the HDD. Partition A contains the following data: added fonts, forms for ART EX, ART IV (optional), PC-PR201H, ESC/P, and HP-GL/2 (optional), ART IV User Defined Data, and SMB folder.

    Initialization Procedure
    Enter UI Diagnostic mode (see Accessing UI Diagnostics). Select Initialize Hard Disk. The Partition A radio button appears.
    Select Partition A then select Start.
    A confirmation message appears. Select Yes.
    A message indicating the completion appears. Select Confirm.
    This completes the initialization of Partition A.

    Still working on the first machine error code i don’t have it in the manual.


System Cont detects [ESS-NVRAM with factory settings is installed] or [Illegal ESS-NVRAM

data is occurring].

Initial Actions

Power Off/On

Procedure

As powering OFF then ON after a detection of 116-334 will presumably cause other errors 124-3xx

that indicate various data mismatches between the three locations, resolve one(s) following the

corrective actions for the relevant Fault Code(s).

If 116-334 reoccurs despite powering OFF/ON, disconnect and reconnect the NV-RAM Board,

then turn ON the power.

If the problem persists, replace the NV-RAM Board.

If the problem still persists, replace the mercury battery.

Launch Version

WorkCentre 5225, 5230

116-335 HDD RAP

The control logic detected that the HDD failed.

Initial Actions

Power Off/On

Procedure

Check the HDD electrical connections

If the problem persists perform

If the problem persists replace the HDD

February, 2008

2-597

(PL

9.2).

Hard Disk Diagnostic

Program.

(PL

9.2).

116-334, 116-335

Status Indicator Raps

  1. 10-07-2015

    #1

    jmandassociates is offline


    Senior Tech

    100+ Posts


    Rep Power
    31

    Xerox Color 570 errors 116-334 and 116-312

    Working on 2 Xerox Color 570 we just got in both with problems. Previous owner kept the hard drives. We replaced them with 80GB sata hard drives we had laying around. Not sure if they need to be Xerox specific and that could be part of the problem.

    The first machine the first time you power it on it will get to step 2/6 in the initial loading process and then an error message �please reboot 116-334� pops up. I reboot and no longer got this error but it freezes on step 2/6 of loading process. It will stay stuck on this screen until you restart the copier, but will freeze on this same 2/6 screen every time after that (no more �please reboot 116-334� error). If you totally unplug the copier and try to start it again, you will get the �please reboot 116-334� error message again, only the first time, and then will freeze on 2/6 every other time you restart the copier.

    The second machine loads to fault/error screen with code: 116-312 every time

    Any help would be greatly appreciated.


  2. 10-07-2015

    #2

    Jake2o is offline


    Senior Tech

    250+ Posts

    Jake2o's Avatar


    Rep Power
    35

    Re: Xerox Color 570 errors 116-334 and 116-312

    Quote Originally Posted by jmandassociates
    View Post

    Working on 2 Xerox Color 570 we just got in both with problems. Previous owner kept the hard drives. We replaced them with 80GB sata hard drives we had laying around. Not sure if they need to be Xerox specific and that could be part of the problem.

    The first machine the first time you power it on it will get to step 2/6 in the initial loading process and then an error message �please reboot 116-334� pops up. I reboot and no longer got this error but it freezes on step 2/6 of loading process. It will stay stuck on this screen until you restart the copier, but will freeze on this same 2/6 screen every time after that (no more �please reboot 116-334� error). If you totally unplug the copier and try to start it again, you will get the �please reboot 116-334� error message again, only the first time, and then will freeze on 2/6 every other time you restart the copier.

    The second machine loads to fault/error screen with code: 116-312 every time

    Any help would be greatly appreciated.

    Machine 2 for certain thhis is what the error code means
    An error was detected in the HDD encryption key during activation.Procedure

    • Switch the power Off, then On. If the problem still exists, perform the following:
    • Refer to the Initialize Hard Disk Procedure in UI Diagnostics. Listed below
    • If the problem still exists, replace the HDD ( PL 11.6).
    • When the system has been recovered, set the HDD encryption key.

    This routine initializes Partition A of the HDD. Partition A contains the following data: added fonts, forms for ART EX, ART IV (optional), PC-PR201H, ESC/P, and HP-GL/2 (optional), ART IV User Defined Data, and SMB folder.

    Initialization Procedure
    Enter UI Diagnostic mode (see Accessing UI Diagnostics). Select Initialize Hard Disk. The Partition A radio button appears.
    Select Partition A then select Start.
    A confirmation message appears. Select Yes.
    A message indicating the completion appears. Select Confirm.
    This completes the initialization of Partition A.

    Still working on the first machine error code i don’t have it in the manual.


Решение проблем

Xerox

® 

WorkCentre

® 

5022/5024 Multifunction Printer

User Guide

13-48

092-660

Ошибка принт-картриджа.

Выключите аппарат и снова включите 
его после того, как погаснет дисплей.

092-661

Значение температуры SNR (в заменяемом 
пользователем модуле) выходит за пределы 
установленного диапазона.

Выключите аппарат и снова включите 
его после того, как погаснет дисплей.

092-668

Значение ATC SNR (в принт-картридже) 
выходит за пределы установленного 
диапазона.

Выключите аппарат и снова включите 
его после того, как погаснет дисплей.

092-910

Произошла ошибка.

Выключите аппарат и снова включите 
его после того, как погаснет дисплей.

093-312

Ошибка тонер-картриджа.

Выключите аппарат и снова включите 
его после того, как погаснет дисплей. 
Если снова появится данное сообщение, 
обратитесь в центр технической 
поддержки Xerox.

093-400

В тонер-картридже закончился тонер.

Замените тонер-картридж.

093-406

Необходимо вскоре заменить тонер-
картридж.

Приготовьте новый тонер-картридж.

093-912

В тонер-картридже закончился тонер. 

Замените тонер-картридж.

093-956

Ошибка принт-картриджа. 

Удалите ленту с принт-картриджа. 
См. раздел 

093-959

Ошибка принт-картриджа.

Замените принт-картридж. При 
обращении в центр технической 
поддержки Xerox для заказа расходных 
материалов (периодически заменяемых 
модулей) сообщайте товарные коды.
См. раздел 

116-321
116-323
116-324

116-334
116-377

Произошла ошибка.

Выключите аппарат и снова включите 
его после того, как погаснет дисплей. 
Если снова появится данное сообщение, 
обратитесь в центр технической 
поддержки Xerox.

116-386

Неправильно подключен кабель факса.

Надежно подключите кабель, выключите 
аппарат и снова включите его после того, 
как погаснет дисплей. Если снова 
появится данное сообщение, обратитесь 
в центр технической поддержки Xerox.

116-747

Не удается выполнить сканирование, т. к. 
слишком мала область сканирования.

Уменьшите значение для стирания краев 
или масштаб.

Код 
ошибки

Причина

Устранение

  • 14 Май 2015

Приветствую всех . Есть 3 аппарата Xerox WC 5222 но 1 начал выдавать Ошибка 116-324 . По поиску в интернете нашёл что виновата оперативная память . Поменял их местами с заведомо рабочего аппарата и нерабочего , толку ноль … Но есть ещё 1 нюанс если его выдернуть из сети то он запускается и работает без ошибки — копирует всё нормально . Как только его подключаешь в сеть сразу выдаёт ошибку — «Сохранение данных » и с низу ошибка 116-324 .
На плате стоит жесткий диск и ещё 1 платка с энерго независимой памятью 24С02.
Как я понял в платке 24с02 хранятся лицензионные ключи и какие то настройки . в жестком диске ПО , Не могу понять что глючит в этом аппарате .
Или дайте кто нибудь сервисный мануал на xerox WC 5222/25/30 на почту.

Только что прогнал жёсткий диск через викторию всё нормально

  • 14 Май 2015

Только что прогнал жёсткий диск через викторию всё нормально
а сколько на нем места свободного?

  • 14 Май 2015

kostya666, На компьютере разделы не определились , проверял жесткий диск Викторией на битые сектора …
Можно как то через веб интерфейс посмотреть в аппарате сколько места в нём ?

  • 14 Май 2015

SisDan сказал(а):

Можно как то через веб интерфейс посмотреть в аппарате сколько места в нём ?

думаю да. проверь сколько там свободно.

SisDan сказал(а):

о есть ещё 1 нюанс если его выдернуть из сети то он запускается и работает без ошибки — копирует всё нормально . Как только его подключаешь в сеть сразу выдаёт ошибку — «Сохранение данных » и с низу ошибка 116-324 .

может конфликтует с сеткой?

  • 14 Май 2015

kostya666, Проверил жесткий — он пустой полностью — проверял через Acronis .

После смены настроек на DHCP сервере и смены IP адреса на назначение принтеру -(Поставил другой ИП на аппарате) Он включился вместе с сеткой ! Значит что то не то шло с какого то компа который был завязан на него !
Найду причину отпишусь .

Добавлено 14-05-2015 14:52

kostya666, У меня вот такой вопрос разница между прошивками какая — v1.207.8 PS Firmware and Installation Instructions и v1.207.8 STD firmware and Installation Instructions
Чем они отличаются ? Просто хочу перепрошить аппарат на всякий случай

  • 14 Май 2015

SisDan, не мучай исправный аппарат, он скорее всего завязан на принтсервер, потому без него и выскакивает ошибка. Перенастроить как нужно клиенту, взять за это денег и никуда не лазить, пока не убил в нём что-нибудь, прошивальщик хренов.

  • 14 Май 2015

Генчик, С техникой давно общаюсь , и именно этот аппарат уже не первый раз выкобенивается … 2 остальных работают без проблем . Да и аппарат разобран денег взять не получится я зарплату за ремонт техники получаю
принт сервер у него встроенный .
Да и сам аппарат авторизуется в актив директории в доменной сети .

  • 14 Май 2015

SisDan, ты объясни толком, аппараты в твоей конторе стоят? Сисадмин есть? Ну явно же не железная проблема.

  • 14 Май 2015

Генчик, Да аппараты стоят у нас на в конторе и я их обслуживаю . Просто не понятно почему глючит 1 аппарат . Все аппараты проработали 4,5 года последний год глючит только 1 , чистку и ТО делал , В скором времени запланирована замена печки .

Я уже писал по другой ошибки но там проблема была в шлейфе автоподатчика — заменил на который я сам своял из стах принтеров и проблема исчезла .

  • 14 Май 2015

SisDan, Не надо ни чего прошивать, настрой сетку нормально и забудь!
Аппарат исправный, конфликт по IP скорее всего!

  • 14 Май 2015

kostya666, Раздачей IP занимается СЕРВАК у нас DHCP — динамические IP Адреса .
С сеткой всё нормально .

  • 14 Май 2015

SisDan сказал(а):

принт сервер у него встроенный .

SisDan, нет там никакого принт-сервера, просто обычный сетевой принтер оффисного уровня.

SisDan сказал(а):

Да и сам аппарат авторизуется в актив директории в доменной сети .

SisDan, вот об этом я тебе и говорю, что проблема не в самом аппарате, а в настройках доменного принт-сервера. Если ты поменяешь местами этот аппарат с таким-же из двух других, естественно поменяв соответствущие настройки, то 99% начнёт глючить другой, а этот будет преспокойно работать в другом месте.

Добавлено 14.05.2015 13:25

SisDan сказал(а):

Вот это весьма сомнительно.
SisDan, если ты сам там сисадмин, то бегом учить системную матчасть. Если сисадмин кто-то другой, то нагнуть его проверить все настройки принтсервера для этого аппарата.
А вообще гнать его метлой из сисадминов за динамический IP для сетевых принтеров. Большей глупости придумать невозможно.

  • 14 Май 2015

Генчик, начнём по порядку , 1. DHCP сервак по мак адресу назначает IP Адрес принтеру По зарезервированным адресам для принтеров .
2. Пользователь отсылает на печать на IP Адрес принтера — Напрямую минуя сервак .
3. Если нужно от сканировать это делается с самого Аппарата по настроенному шаблону — И только по шаблону принтер авторизуется в актив директории и отсылает обратно .

Добавлено 14-05-2015 15:30

Ошибка 116-324

15.03.2013

Модель: Xerox WorkCentre 5225

Здравствуйте, выходит ошибка 116-324, но только когда мфу подключен к сети? Что делать?

Ответ:

Данная ошибка означает, что возникли проблемы с оперативной памятью аппарата, т.е. вам нужно заменить плату RAMDIM.

Добавлено 14-05-2015 15:31

Это ответ Альфатех

  • 14 Май 2015

SisDan сказал(а):

1. DHCP сервак по мак адресу назначает IP Адрес принтеру По зарезервированным адресам для принтеров .

SisDan, это правильно. Ещё правильнее делать так и для всех сетевых девайсов, включая компы.

SisDan сказал(а):

2. Пользователь отсылает на печать на IP Адрес принтера — Напрямую минуя сервак .

SisDan, куйня полная! Никакого контроля и возможности админу вмешаться в процесс печати. Если какой-нибудь дебил захочет завалить аппарат заданиями на печать, у него есть все возможности для этого.

SisDan сказал(а):

3. Если нужно от сканировать это делается с самого Аппарата по настроенному шаблону — И только по шаблону принтер авторизуется в актив директории и отсылает обратно .

SisDan, ну хоть что-то сделали правильно.

SisDan сказал(а):

Данная ошибка означает, что возникли проблемы с оперативной памятью аппарата, т.е. вам нужно заменить плату RAMDIM.

SisDan, куйня полная! Какой-то дебил юзверь гонит на печать немерянное количество куйни, а из-за отсутствия принтсервера и очереди печать на нём, происходит переполнение буфера аппарата. Сконфигурировать правильно принт-сервер в домене и забыть об этой ошибке.

  • 14 Май 2015

Генчик, Аппарат стоит прямо в кабинете в отделе у пользователей ! Пусть заваливает спрос с пользователя будет . Расходные материалы ограничены на каждый отдел ) Переборщили или сломали — сидят без принтера .

Добавлено 14-05-2015 15:43

Генчик, Сервак перенастроил пока ни кто не отсылает на печать он в сети работает … Пойду перенастрою пользователей и посмотрю на каком именно он встанет в ошибку . По результатам отпишусь .

  • 14 Май 2015

SisDan сказал(а):

Аппарат стоит прямо в кабинете в отделе у пользователей ! Пусть заваливает спрос с пользователя будет .

SisDan, балбес, они уже завалили, а ипёшся ты. и спрос тоже с тебя.

  • 14 Май 2015

Прикольно, у меня знакомые админы на такую технику ставят фиксированные адреса, а не динамические.
В драйвере прописывают принтер/МФУ и работают.
А то питание выключишь, включишь и ищи своё устройство…

  • 14 Май 2015

Владимир Анатольевич сказал(а):

у меня знакомые админы на такую технику ставят фиксированные адреса, а не динамические.

Владимир Анатольевич, а там и получается фиксированный адрес, поскольку в AD (домене) прописывается фиксированный IP для определённого MAC. Ты бы не лез обсуждать то, в чём ни хрена не понимаешь.

  • 15 Май 2015

Генчик, Посмотрел ЛОГ принтера с утра и Логе весели ошибки — 026-714 proxy — Склонирова с рабочего аппарата настройки на него и подправил шаблоны под их отдел — пол дня отработали больше ошибок не было
Всем Спасибо за помощь .

Добавлено 15-05-2015 12:45

Генчик, Спасибо за подсказку по настройке — буду читать по настройке принт сервиса на 2008 серваке и попробую поднять сначала на виртуальной машине а потом на нашем сераваке попробую !

Тему можно считать закрытой .

Возможно, вам также будет интересно:

  • Xerox workcentre 5021 ошибка 092910
  • Xerox workcentre 5021 ошибка 092 910
  • Xerox workcentre 5021 ошибка 092 668
  • Xerox workcentre 5021 ошибка 062 396
  • Xerox workcentre 5021 ошибка 062 360

  • Понравилась статья? Поделить с друзьями:
    0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии