Code
Description
1
Leakage current
2
Missing phase
3
External fault
Too many pump auto-
4
restarts per 24 h
6
Mains supply fault
Motor-phase sequence
9
reversal
Pump (power line)
10
communication fault
Water-in-oil content too
11
high
Motor operating-time
12
service interval limit
exceeded
15
SCADA callback fault
16
Other fault
Capacity too low
17
(Performance
requirements not met)
Motor protector
18
commanded (test) trip
Diaphragm break — dosing
19
pump
Motor insulation resistance
20
low
Motor max. starts per hour
21
limit exceeded
22
Motor moisture switch
24
Motor/pump vibration high
25
Setup conflict
Load continues despite
26
motor relay is off
Motor protector activated
27
via DI
Change bearings (specific
30
service information)
32
Motor high voltage
33
Soon time for service
Gas in pump head,
35
deaerating problem
36
Pressure valve leakage
37
Suction valve leakage
38
Venting valve defect
18
Origin
Cause
CUE
Leakage current detected
MP
Phase disconnected
204/CUE
MP 204/IO
351/IO
Fault in external module
113/CUE
MP 204
Overcurrent
MP
Phase missing or drifted
204/CUE
MP 204
Phases interchanged
IO 113
Communication to SM 113 Check cables between IO 113 and SM 113.
IO 113
Water-in-oil compartment
CU 362
Service interval
CU 362
SCADA failed to respond
CUE
Fault reported by CUE
Dosing
Dosing volume not met
pump
MP 204
Test trip activated
Dosing
Diaphragm break detected Replace diaphragm in dosing pump.
pump
IO 113/MP
Insulation resistance
204
too low
CU 362
Max. starts exceeded
IO 113
Moisture switch activated
Vibration threshold
IO 113
exceeded
IO 113
Setup conflict in IO 113
Current drawn when it
MP 204
should not be
CU 362
Motor protection tripped
Change bearings reported
CUE
by CUE
MP
Voltage too high
204/CUE
Dosing
Service interval is close
pump
Dosing
Gas in pump head
pump
Dosing
Pressure valve leakage
Pump
Dosing
Suction valve leakage
pump
Dosing
Venting valve defect
pump
Remedy
Check CUE local HMI for fault description.
Check pre-fuses and circuit breakers.
Check all external modules connected via GENIbus.
Check pump, valves and pipes for blockages.
Check voltages between phases, pre-fuses and circuit
breakers.
Check phase sequence.
Water-in-oil content has passed threshold. Lower shaft-
seal and oil needs replacement.
User-defined service interval has been reached.
Arrange for preventive maintenance.
Check cellular network connection. Check if SCADA
phone number is correct. Check status of external
SCADA system.
Check fault locally on CUE drive.
Check status of dosing pump. Perform calibration
of dosing pump.
Test trip activated on MP 204.
Check setting. Motor may need replacement.
User setting of max. number of starts exceeded.
Evaluate setting. Evaluate stop and start levels to
increase pump runtime.
Moisture or water detected inside motor. Overhaul of
pump or motor is needed.
Check pump, valves and pipes for blockages. Pump
may need overhaul.
Check settings of DIP switches of IO 113. Check
warning and alarm threshold in IO 113 by using PC Tool
Water Utility.
Check motor relay (possibility of contact welding).
Check possible causes for tripping. Check pump,
valves and pipes for blockages.
Check local alarms and instructions on CUE.
Voltage on one or multiple phases is too high. Check
incoming voltage.
User-defined service interval is close. Arrange for
preventive maintenance on dosing pump.
Check the installation and operating instructions of
the dosing pump for remedy.
Check the installation and operating instructions of
the dosing pump for remedy.
Check the installation and operating instructions of
the dosing pump for remedy.
Check the installation and operating instructions of
the dosing pump for remedy.
- Manuals
- Brands
- Grundfos Manuals
- Measuring Instruments
- CU 362
Manuals and User Guides for Grundfos CU 362. We have 2 Grundfos CU 362 manuals available for free PDF download: Installation And Operating Instructions Manual
-
G-858BP Backpack Mag Cesium Vapor Magnetometer Operation Manual COPYRIGHT © DECEMBER 2010 P/N 25271-OM Rev. A GEOMETRICS, INC. 2190 Fortune Drive, San Jose, CA 95131 USA Phone: (408) 954-0522 Fax: (408) 954-0902 …
G-858BP Measuring Instruments, 108
-
Turning ___________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ …
SINUMERIK 840D sl Controller, 714
-
PFDWinAIR Compact Differential GaugeInstructions and Maintenance ManualWINTERS INSTRUMENTS Tel: 1-800-WINTERS / www.winters.comDimensions (mm)SpecicationsDial 2 1/16” (52.4mm), white aluminum with black markingsCase Glass lled nylon, blackLens PolycarbonateRing Threaded die-cast black aluminumProcess Connections 3/16″ barbed for ID tubingMovement Resistance-free a …
WinAIR PFD Series Measuring Instruments, 2
-
Rain Master Irrigation Systems DX2 User Manual Page 232 Appendix A: Flow Meters Appendix A Flow Meters The Evolution DX2 series controller provides a variety of user-configurable, flow-related features for either one or two flow sensors, referred to as Flow #1 and Flow #2. The Evolution DX2 flow features/capabilities include: • Display of instantaneous flow rate in …
DX2 series Measuring Instruments, 22
-
IInnssttrruuccttiioonn MMaannuuaallMMaannuuaall ddee IInnssttrruucccciioonneessMMaannuueell dd’’IInnssttrruuccttiioonnssMMaannuuaallee ddii IIssttrruuzziioonniiBBeeddiieennuunnggssaannlleeiittuunnggIInnssttrruuççõõeess ddee UUttiilliizzaaççããooModels56-DGT2 56-DGT10Electronic DigitalTransit/TheodoliteINSTRUCTION MANUAL …
56-DGT2 Measuring Instruments, 92
-
[ https://berlin.museum-digital.de/index.php?t=objekt&oges=47043 (04.02.2021) ]Bedienungsanleitung: Bedienungsanleitung TelefunkenMagnetophon 70Deutsches Technikmuseum- Inv. Nr:I.2.060 P-Tfk 03214Bedienungsanleitung Telefunken Magnetophon 70Telefunken Magnetophon 70Mehrsprachige Bedienungsanleitung f¨ur das Tonbandger¨at Telefunken Mag-netophon 70 mit illustrierter Beschr …
Magnetophon 70 Measuring Instruments, 10
-
Products Solutions ServicesBrief Operating InstructionsLiquiline Control CDC90Automated cleaning and calibration of MemosenssensorsThese Instructions are Brief Operating Instructions; they arenot a substitute for the Operating Instructions pertaining tothe device.Detailed information on the device can be found in theOperating Instructions and in the other documentationavailable …
Liquiline Control CDC90 Measuring Instruments, 72
-
10864EN March 2017Metering systeMsSatellite with electronic regulationge556Y404 (ge556-2 SerieS)047U57228• Self-modulating circulator 15/6, centre distance 130 mm, complying with ErP directive (2009/125/CE).• Heat exchanger and fully insulated piping.• WRAS-certied components for the sanitary circuit.• Spacers for inserting the meters.• Painted sheet metal cabinet …
GE556-2 Series Measuring Instruments, 6
-
MO25‐EN‐SP‐DE‐FR‐IT‐PTv1.13/14123451234512345MO25MOISTUREMETERUSERGUIDEIntroductionThe MO25 measures moisture (%WME) in wood, brick, concrete,paper,&fabricandtracesleakageinsidewalls,ceilings,andfloors.Descri …
MO25 Measuring Instruments, 2
-
Instructions050-3635-00Inverter Board and Cable Replacement KitTLA715 and TLA7UPTDS5000, TDS6000, CSA/TDS7000, CSA/TDS8000,TLA600, and VM5000 Series075-0908-00*P075090800*075090800WarningThe servicing instructions are for use by qualifiedpersonnel only. To avoid personal injury, do notperform any servicing unless you are qualified todo so. Refer to all safety summaries prior to …
TLA715 Series Inverter, 10
-
NOYAFA
NF-820
Anti-jamming underground cable detectorVER: V4NF-820Your excellent helper in cable test!ORIGINAL AUTHENTICed produntctetsa,Ping noteit arfltelonwueodCORIGINAL AUTHENTICYour excellent helper in cable test!INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL …
NF-820 Measuring Instruments, 7
-
VOLTCRAFT
DT-30LK
BedienungsanleitungDT-30LK DrehzahlmesserBest.-Nr. 1012206Seite 2 — 16Operating InstructionsDT-30LK TachometerItem No. 1012206 Page 17-31Mode d’emploiDT-30LK Compte Tours/MinNº de commande 1012206 Page 32-46GebruiksaanwijzingDT-30LK ToerentalmeterBestelnr. 1012206 Pagina 47-63 …
DT-30LK Measuring Instruments, 64
-
Kusam-meco
KM 3060
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai — 400 015. INDIA.Sales Direct.: 022-24156638, Tel. : 022-24124540, 24181649, Fax : 022-24149659Email : [email protected], Website : www.kusamelectrical.comAll Specifications are subject to change without prior noticeGENERAL SPECIFICATIONS :AC Current : 0.01A ~ 1000AAC Voltage : 1V ~ 75 …
KM 3060 Measuring Instruments, 7