Gpo ошибка 1612 при установке

  • Remove From My Forums
  • Question

  • Hi,

    I have Windows 20018 R2 DC. I want to deploy msi package through GPO. I got error on client’s computer saying «The install of application from policy failed.  The error was : %%1612». What could be the problem? Where should I look into?

    Any help will be appreciated!

    Thanks in advance!


    Grace

Answers

  • Hi,

    Try add Everyone group Read permission in the  folder where you have the .msi installer. by adding authenticated user wont help, add everyone group  to Read

    Thanks

    Syed. 


    Dont forget to mark as Answered if you found this post helpful.

    • Edited by

      Wednesday, April 25, 2018 2:15 AM

    • Marked as answer by
      graceyin39
      Wednesday, April 25, 2018 3:08 PM

  • > «The install of application from policy failed.  The error was : %%1612».

    ERROR_INSTALL_SOURCE_ABSENT      1612     The installation source for this product is not available. Verify that the source exists and that you can access it.

    As already pointed out: The computer account cannot access the MSI file. Do Domain Computers (or Auth Users) have read access on both share and ntfs level?

    • Marked as answer by
      graceyin39
      Wednesday, April 25, 2018 3:09 PM

  • Remove From My Forums
  • Question

  • Hi,

    I have Windows 20018 R2 DC. I want to deploy msi package through GPO. I got error on client’s computer saying «The install of application from policy failed.  The error was : %%1612». What could be the problem? Where should I look into?

    Any help will be appreciated!

    Thanks in advance!


    Grace

Answers

  • Hi,

    Try add Everyone group Read permission in the  folder where you have the .msi installer. by adding authenticated user wont help, add everyone group  to Read

    Thanks

    Syed. 


    Dont forget to mark as Answered if you found this post helpful.

    • Edited by

      Wednesday, April 25, 2018 2:15 AM

    • Marked as answer by
      graceyin39
      Wednesday, April 25, 2018 3:08 PM

  • > «The install of application from policy failed.  The error was : %%1612».

    ERROR_INSTALL_SOURCE_ABSENT      1612     The installation source for this product is not available. Verify that the source exists and that you can access it.

    As already pointed out: The computer account cannot access the MSI file. Do Domain Computers (or Auth Users) have read access on both share and ntfs level?

    • Marked as answer by
      graceyin39
      Wednesday, April 25, 2018 3:09 PM

Hi,

Got a very similar problem to the one here except it is only affecting one application.

http://community.spiceworks.com/topic/145872-group-policy-software-deployment-via-dfs-path-fails?pag…

I have enabled verbose logging on the client machine I am testing for application management and the output shows that the network source path is invalid due to missing or inaccessible package.

I have validated that the DFS share is available via a interactive logon and the package exists.

Not sure what to do next, any assistance much appreciated.

Sean

Ещё около полугода назад столкнулись мы с ситуацией когда на новые компьютеры (особо быстрые с SSD) упорно не ставится управляемое программное обеспечение (опубликованное в AD GPO). При инициализации операционной систему (в нашем случае это Windows 7) появляется сообщение:

Имя журнала: System
Источник: NETLOGON
Дата: 25.05.2018 19:25:53
Код события: 5719
Категория задачи:Отсутствует
Уровень: Ошибка
Ключевые слова:Классический
Пользователь: Н/Д
Компьютер: CompName-27.domain.local
Описание:
Компьютер не может установить безопасный сеанс связи с контроллером домена DOMAIN по следующей причине:
Отсутствуют серверы, которые могли бы обработать запрос на вход в сеть.
Это может затруднить проверку подлинности. Убедитесь, что компьютер подключен к сети. Если ошибка повторится, обратитесь к администратору домена.
Дополнительные сведения
Если данный компьютер является контроллером указанного домена, он устанавливает безопасный сеанс связи с эмулятором основного контроллера этого домена. В противном случае компьютер устанавливает безопасный сеанс связи с произвольным контроллером данного домена.
Xml события:
<Event xmlns=»http://schemas.microsoft.com/win/2004/08/events/event»>
  <System>
    <Provider Name=»NETLOGON» />
    <EventID Qualifiers=»0″>5719</EventID>
    <Level>2</Level>
    <Task>0</Task>
    <Keywords>0x80000000000000</Keywords>
    <TimeCreated SystemTime=»2018-05-25T16:25:53.000000000Z» />
    <EventRecordID>6250</EventRecordID>
    <Channel>System</Channel>
    <Computer>CompName-27.domain.local</Computer>
    <Security />
  </System>
<EventData>
  <Data>DOMAIN</Data>
  <Data>%%1311</Data>
  <Binary>5E0000C0</Binary>
</EventData>
</Event>

Потом валится куча ошибок о том, что не удалось установить приложение

Имя журнала: System
Источник: Application Management Group Policy
Дата: 25.05.2018 20:02:53
Код события: 102
Категория задачи:Отсутствует
Уровень: Ошибка
Ключевые слова:Классический
Пользователь: СИСТЕМА
Компьютер: CompName-26.domain.local
Описание:
Не удалось установить приложение 1С Регистрация баз x64 из политики Общие — 1C Приложения. Ошибка: %%1612
Xml события:
<Event xmlns=»http://schemas.microsoft.com/win/2004/08/events/event»>
  <System>
    <Provider Name=»Application Management Group Policy» />
    <EventID Qualifiers=»0″>102</EventID>
    <Level>2</Level>
    <Task>0</Task>
    <Keywords>0x80000000000000</Keywords>
    <TimeCreated SystemTime=»2018-05-25T17:02:53.000000000Z» />
    <EventRecordID>6827</EventRecordID>
    <Channel>System</Channel>
    <Computer>CompName-26.domain.local</Computer>
    <Security UserID=»S-1-5-18″ />
  </System>
  <EventData>
    <Data>1С Регистрация баз x64</Data>
    <Data>Общие — 1C Приложения</Data>
    <Data>1612</Data>
  </EventData>
</Event>

Ну и в финале сообщение что не удалось применить параметры «Software Installation»

Имя журнала: System
Источник: Microsoft-Windows-GroupPolicy
Дата: 25.05.2018 20:02:57
Код события: 1085
Категория задачи:Отсутствует
Уровень: Предупреждение
Ключевые слова:
Пользователь: СИСТЕМА
Компьютер: CompName-26.domain.local
Описание:
Windows не удалось применить параметры «Software Installation». Параметры «Software Installation» могут иметь свой собственный файл журнала. Щелкните ссылку «Дополнительные сведения».
Xml события:
<Event xmlns=»http://schemas.microsoft.com/win/2004/08/events/event»>
  <System>
    <Provider Name=»Microsoft-Windows-GroupPolicy» Guid=»{AEA1B4FA-97D1-45F2-A64C-4D69FFFD92C9}» />
    <EventID>1085</EventID>
    <Version>0</Version>
    <Level>3</Level>
    <Task>0</Task>
    <Opcode>1</Opcode>
    <Keywords>0x8000000000000000</Keywords>
    <TimeCreated SystemTime=»2018-05-25T17:02:57.757400000Z» />
    <EventRecordID>6864</EventRecordID>
    <Correlation ActivityID=»{54535425-A285-47E9-978C-6FEC24263FAC}» />
    <Execution ProcessID=»672″ ThreadID=»1348″ />
    <Channel>System</Channel>
    <Computer>CompName-26.domain.local</Computer>
    <Security UserID=»S-1-5-18″ />
  </System>
  <EventData>
    <Data Name=»SupportInfo1″>1</Data>
    <Data Name=»SupportInfo2″>4432</Data>
    <Data Name=»ProcessingMode»>1</Data>
    <Data Name=»ProcessingTimeInMilliseconds»>9219</Data>
    <Data Name=»ErrorCode»>1612</Data>
    <Data Name=»ErrorDescription»>Ресурс с установочными файлами для этого продукта недоступен. Проверьте существование ресурса и доступ к нему. </Data>
    <Data Name=»DCName»>\DOMAIN-DC20.domain.local</Data>
    <Data Name=»ExtensionName»>Software Installation</Data>
    <Data Name=»ExtensionId»>{c6dc5466-785a-11d2-84d0-00c04fb169f7}</Data>
  </EventData>
</Event>

Ну и в финале сообщение что не удалось применить параметры «Software Installation»

Решения которые нам помогли (в разное время разные решения и на разных компьютерах разная комбинация).

  1. В GPO для всех пользовательских компьютеров заменили значение реестра для параметра DisableDHCPMediaSense c «0» на «1». Подробнее тут
  2. В GPO включили параметр «Выполнять эти программы при входе в систему» (Компьютер/Административные шаблоны/Система/Вход в систему).

если эти два параметра не помогают (на совсем новых компьютерах как раз и проявилось на днях), тогда ещё два параметра руками правим в реестре (на днях наверное напишем скрипт что бы банально на все 100% компьютеров заменять).

  1. KEY_LOCAL_MACHINESYSTEMCurrentControlSetServicesTcpipParametersInterfaces{GUID} в параметре DhcpConnForceBroadcastFlag (REGDWORD) значение «0» заменяем на «1».
  2. HKEY_LOCAL_MACHINESYSTEMCurrentControlSetServicesTcpipParametersInterfaces{GUID} в параметре DhcpConnEnableBcastFlagToggle (REGDWORD) ставим «0». Если параметра нет, создаём его.

Если и это не помогло, тогда:

  1. Обновление BIOS (вообще у нас правило BIOS всегда обновлять, но не все исполнители отличаются исполнительностью, а иногда нет на это ресурсов.
  2. Обновление драйвера сетевого адаптера от производителя MainBoard или сетевой карты.
  3. Отключение ВСЕХ дополнительных функций н параметрах сетевого адаптера. Оставляем включенным только «Включение по сети» и всё.

На сейчас такой порядок действий решает проблему.

Желаем всем коллегам удачи в нашей не лёгкой работе.

Greetings!

I have a strange issue going on in my environment that has me beating my head against the wall.

Windows 2003 Domain — 3 2003 Domain controllers running DNS & WINS.
DFS Root — 3 domain controllers all as root replicas
DFS Target — 1 2003 Windows server hosting all software to be deployed
Affected Clients — any OS I’ve deployed software to — XP, 7, 2003, 2008

Software installation has worked fine, but stopped working abruptly in the past week or so.

The error in the logs of the clients who fail to install the software is event ID 105: the install of %software% from policy %GPO-NAME% failed — the error was %1612.  This indicates that the share is unavailable for whatever reason.  I can login to the machine and access the share fine.  We also have other DFS targets that appear to be working correctly for our User home directories and other shared files for the orginization.

I do not think it is permissions on the shares/ntfs, but as a troubleshooting step I added everyone full control to the share and NTFS permissions.  This caused no change in the problem.

I think the problem is DFS related because I created a new test GPO and pushed some software from it using the straight UNC path to the share on the server (\serversjare) and the software installed correctly.

Does anyone have any ideas for me to start looking at?  I am majorly confused because the DFS environment seems to be working correctly since we have 8 total DFS targets on this single root and they all work correctly.

I have used PSEXEC to open a remote command prompt as SYSTEM from a problematic computer to the share via DFS name and I get access denied.  This tells me that is my problem, but I don’t know how to manipulate the permissions to be correct in this instance, nor do I understand why I would need to do that.  It has worked in the past with no problems.  There were no changes to the permissions (to my knowledge).

From the command prompt as SYSTEM, I can start an install of any of the software on the share using msiexec /i \serversharesoftwareinstaller.msi — but not using the DFS path.

I don’t think this is a permissions problem, rather a DFS problem.

Can anyone lend a hand here?  I would be most grateful.  Thank you!

Adam

Возможно, вам также будет интересно:

  • Gpedit msc выдает ошибку
  • Gpedit msc windows 10 ошибка групповой политики
  • Gparted проверка диска на ошибки
  • Gparted ошибка ввода вывода
  • Gparted linux проверка на ошибки

  • Понравилась статья? Поделить с друзьями:
    0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии