Thanks. Now I can help you…
Network Controller: 2nd driver on the left (64 bit).
https://downloadcenter.intel.com/download/25835/Intel-PROSet-Wireless-Software-and-Drivers-for-Windo…
Bluetooth driver for that card…
This package contains the driver installation package for the Intel Bluetooth in the supported notebook models running a supported operating system.
ftp://ftp.hp.com/pub/softpaq/sp74501-75000/sp74755.exe
PCI Data Acquisition and Signal Processing Controller & ACPIINT3400:
This package contains the driver that enables the Intel Dynamic Platform and Thermal Framework firmware. Intel Dynamic Platform and Thermal Framework provide system temperature and power utilization information for the system thermal protection to function properly. This package is provided for supported notebook models running a supported operating system.
File name: sp72106.exe
PCI Device:
This package contains the driver that enables the Realtek Card Reader in supported notebook models that are running a supported operating system. The card reader enables users to read from or write to supported removable storage cards, which are typically used in digital cameras, digital music players, and cellular phones.
File name: sp71365.exe
PCI Simple Communications Controller:
This package provides the Intel Management Engine Components Driver for supported notebook models running a supported operating system.
ftp://ftp.hp.com/pub/softpaq/sp74501-75000/sp74844.exe
ACPIHPQ6007:
This package provides HP 3D DriveGuard Software (HP ProtectSmart Hard Drive Protection) for supported notebook models that are running a supported operating system. HP 3D DriveGuard Software protects the hard drive by parking the heads if the notebook is accidentally dropped, or is abruptly impacted by another object.
File name: sp71811.exe
ACPIMSFT0101: Run the hotfix from the link below…
https://support.microsoft.com/en-us/kb/2920188
RE: Crash…
Таакс,заметил ошибку что драйвера видеокарты у меня не обновляются
Вот ошибка :
[1520:1578][2017-03-14T22:25:38]i001: Burn v3.7.1224.0, Windows v6.2 (Build 9200: Service Pack 0), path: C:UsersUserDownloadsIntel ComponentsSetupChipset.exe, cmdline: ‘-burn.unelevated BurnPipe.{B867813C-706D-43E5-90E1-1485D8AD96AA} {197D03C8-3C81-430C-B21D-1A6829D973A2} 5468’
[1520:1578][2017-03-14T22:25:38]i000: Initializing string variable ‘IIF_ProductVersion’ to value ‘10.1.1.14’
[1520:1578][2017-03-14T22:25:38]i000: Initializing string variable ‘IIF_InstallerVersion’ to value ‘3.1.6’
[1520:1578][2017-03-14T22:25:38]i000: Initializing string variable ‘IIF_ExtractionMapping_SetupChipsetx86.msi’ to value ‘;NullDrivers.cab;NOT VersionNT64’
[1520:1578][2017-03-14T22:25:38]i000: Initializing string variable ‘IIF_ExtractionMapping_SetupChipsetx64.msi’ to value ‘;NullDrivers.cab;VersionNT64’
[1520:1578][2017-03-14T22:25:41]i000: Setting string variable ‘WixBundleLog’ to value ‘C:UsersUserAppDataLocalTempIntelLogsChipset_20170314222541.log’
[1520:1578][2017-03-14T22:25:41]i000: Setting string variable ‘WixBundleOriginalSource’ to value ‘C:UsersUserDownloadsIntel ComponentsSetupChipset.exe’
[1520:1578][2017-03-14T22:25:41]i052: Condition ‘VersionNT >= v6.1 OR (VersionNT = v6.0 AND NTProductType = 3)’ evaluates to true.
[1520:1578][2017-03-14T22:25:41]i000: Setting string variable ‘WixBundleName’ to value ‘Intel(R) Chipset Device Software’
[1520:1578][2017-03-14T22:25:41]i000: Loading managed bootstrapper application.
[1520:1578][2017-03-14T22:25:41]i000: Creating BA thread to run asynchronously.
[1520:0850][2017-03-14T22:25:41]i000: ** MBA ** Command line:
[1520:0850][2017-03-14T22:25:41]i000: Setting string variable ‘WixBundleName’ to value ‘Программное обеспечение Intel
Chipset Device’
[1520:0850][2017-03-14T22:25:42]i000: ** MBA ** Calling Engine.Detect()
[1520:1578][2017-03-14T22:25:42]i100: Detect begin, 3 packages
[1520:1578][2017-03-14T22:25:42]i000: Setting string variable ‘DotNet35’ to value ‘1’
[1520:1578][2017-03-14T22:25:42]i000: Setting string variable ‘DotNet40Client’ to value ‘1’
[1520:1578][2017-03-14T22:25:42]i000: Setting string variable ‘DotNet40Full’ to value ‘1’
[1520:1578][2017-03-14T22:25:42]i000: Setting string variable ‘DotNet45’ to value ‘394802’
[1520:1578][2017-03-14T22:25:42]i052: Condition ‘DotNet35 OR DotNet40Client OR DotNet40Full OR (DotNet45 >= 378389)’ evaluates to true.
[1520:1578][2017-03-14T22:25:42]i101: Detected package: DotNet45, state: Present, cached: None
[1520:1578][2017-03-14T22:25:42]i101: Detected package: SetupChipsetx86.msi, state: Absent, cached: None
[1520:1578][2017-03-14T22:25:42]i104: Detected package: SetupChipsetx86.msi, feature: NullDriverFeature, state: Absent
[1520:1578][2017-03-14T22:25:42]i104: Detected package: SetupChipsetx86.msi, feature: PackageVersionFeature, state: Absent
[1520:1578][2017-03-14T22:25:42]i104: Detected package: SetupChipsetx86.msi, feature: LicenseAgreementFeature, state: Absent
[1520:1578][2017-03-14T22:25:42]i101: Detected package: SetupChipsetx64.msi, state: Absent, cached: None
[1520:1578][2017-03-14T22:25:42]i104: Detected package: SetupChipsetx64.msi, feature: NullDriverFeature, state: Absent
[1520:1578][2017-03-14T22:25:42]i104: Detected package: SetupChipsetx64.msi, feature: PackageVersionFeature, state: Absent
[1520:1578][2017-03-14T22:25:42]i104: Detected package: SetupChipsetx64.msi, feature: LicenseAgreementFeature, state: Absent
[1520:1578][2017-03-14T22:25:42]i199: Detect complete, result: 0x0
[1520:1578][2017-03-14T22:25:57]i200: Plan begin, 3 packages, action: Install
[1520:1578][2017-03-14T22:25:57]w321: Skipping dependency registration on package with no dependency providers: DotNet45
[1520:1578][2017-03-14T22:25:57]i052: Condition ‘NOT VersionNT64’ evaluates to false.
[1520:1578][2017-03-14T22:25:57]i204: Plan 3 msi features for package: SetupChipsetx86.msi
[1520:1578][2017-03-14T22:25:57]i203: Planned feature: NullDriverFeature, state: Absent, default requested: Unknown, ba requested: Unknown, execute action: None, rollback action: None
[1520:1578][2017-03-14T22:25:57]i203: Planned feature: PackageVersionFeature, state: Absent, default requested: Unknown, ba requested: Unknown, execute action: None, rollback action: None
[1520:1578][2017-03-14T22:25:57]i203: Planned feature: LicenseAgreementFeature, state: Absent, default requested: Unknown, ba requested: Unknown, execute action: None, rollback action: None
[1520:1578][2017-03-14T22:25:57]i052: Condition ‘VersionNT64’ evaluates to true.
[1520:1578][2017-03-14T22:25:57]i204: Plan 3 msi features for package: SetupChipsetx64.msi
[1520:1578][2017-03-14T22:25:57]i203: Planned feature: NullDriverFeature, state: Absent, default requested: Unknown, ba requested: Unknown, execute action: None, rollback action: None
[1520:1578][2017-03-14T22:25:57]i203: Planned feature: PackageVersionFeature, state: Absent, default requested: Unknown, ba requested: Unknown, execute action: None, rollback action: None
[1520:1578][2017-03-14T22:25:57]i203: Planned feature: LicenseAgreementFeature, state: Absent, default requested: Unknown, ba requested: Unknown, execute action: None, rollback action: None
[1520:1578][2017-03-14T22:25:57]i000: Setting string variable ‘WixBundleRollbackLog_SetupChipsetx64.msi’ to value ‘C:UsersUserAppDataLocalTempIntelLogsChipset_20170314222541_0_SetupChipsetx64.msi_rollback.log’
[1520:1578][2017-03-14T22:25:57]i000: Setting string variable ‘WixBundleLog_SetupChipsetx64.msi’ to value ‘C:UsersUserAppDataLocalTempIntelLogsChipset_20170314222541_0_SetupChipsetx64.msi.log’
[1520:1578][2017-03-14T22:25:57]i201: Planned package: DotNet45, state: Present, default requested: Present, ba requested: Present, execute: None, rollback: None, cache: No, uncache: No, dependency: None
[1520:1578][2017-03-14T22:25:57]i201: Planned package: SetupChipsetx86.msi, state: Absent, default requested: Absent, ba requested: Absent, execute: None, rollback: None, cache: No, uncache: No, dependency: None
[1520:1578][2017-03-14T22:25:57]i201: Planned package: SetupChipsetx64.msi, state: Absent, default requested: Present, ba requested: Present, execute: Install, rollback: Uninstall, cache: Yes, uncache: No, dependency: Register
[1520:1578][2017-03-14T22:25:57]i299: Plan complete, result: 0x0
[1520:0850][2017-03-14T22:25:57]i000: Setting string variable ‘IIF_MSI_SWITCHES’ to value »
[1520:0850][2017-03-14T22:25:57]i000: ** MBA ** Getting window handle.
[1520:0850][2017-03-14T22:25:57]i000: ** MBA ** Calling Engine.Apply(). Window handle: 131870
[1520:1578][2017-03-14T22:25:57]i300: Apply begin
[155C:14FC][2017-03-14T22:25:57]i000: Caching bundle from: ‘C:UsersUserAppDataLocalTemp{619e726e-d2b4-4e28-9568-c964fd81ee6c}.beSetupChipset.exe’ to: ‘C:ProgramDataPackage Cache{619e726e-d2b4-4e28-9568-c964fd81ee6c}SetupChipset.exe’
[155C:14FC][2017-03-14T22:25:57]i320: Registering bundle dependency provider: {619e726e-d2b4-4e28-9568-c964fd81ee6c}, version: 10.1.1.14
[155C:1500][2017-03-14T22:25:57]i305: Verified acquired payload: SetupChipsetx64.msi at path: C:ProgramDataPackage Cache.unverifiedSetupChipsetx64.msi, moving to: C:ProgramDataPackage Cache{FEBB7B48-CC1C-4A50-A497-FA21413F6BE9}v10.1.1.14SetupChipsetx64.msi.
[155C:1500][2017-03-14T22:25:57]i305: Verified acquired payload: cab4FADBDD6DC6637E75E196F741A3F14D1 at path: C:ProgramDataPackage Cache.unverifiedcab4FADBDD6DC6637E75E196F741A3F14D1, moving to: C:ProgramDataPackage Cache{FEBB7B48-CC1C-4A50-A497-FA21413F6BE9}v10.1.1.14media1.cab.
[155C:14FC][2017-03-14T22:25:57]i323: Registering package dependency provider: {FEBB7B48-CC1C-4A50-A497-FA21413F6BE9}, version: 10.1.1.14, package: SetupChipsetx64.msi
[155C:14FC][2017-03-14T22:25:57]i301: Applying execute package: SetupChipsetx64.msi, action: Install, path: C:ProgramDataPackage Cache{FEBB7B48-CC1C-4A50-A497-FA21413F6BE9}v10.1.1.14SetupChipsetx64.msi, arguments: ‘ MSIFASTINSTALL=»7″ IIF_MSI_SWITCHES=»» ARPSYSTEMCOMPONENT=»1″‘
[155C:14FC][2017-03-14T22:26:09]e000: Error 0x80070643: Failed to install MSI package.
[155C:14FC][2017-03-14T22:26:09]e000: Error 0x80070643: Failed to execute MSI package.
[1520:1578][2017-03-14T22:26:09]e000: Error 0x80070643: Failed to configure per-machine MSI package.
[1520:1578][2017-03-14T22:26:09]i319: Applied execute package: SetupChipsetx64.msi, result: 0x80070643, restart: None
[1520:1578][2017-03-14T22:26:09]e000: Error 0x80070643: Failed to execute MSI package.
[155C:14FC][2017-03-14T22:26:09]i301: Applying rollback package: SetupChipsetx64.msi, action: Uninstall, path: C:ProgramDataPackage Cache{FEBB7B48-CC1C-4A50-A497-FA21413F6BE9}v10.1.1.14SetupChipsetx64.msi, arguments: ‘ MSIFASTINSTALL=»7″ IIF_MSI_SWITCHES=»» ARPSYSTEMCOMPONENT=»1″‘
[155C:14FC][2017-03-14T22:26:12]e000: Error 0x80070643: Failed to uninstall MSI package.
[155C:14FC][2017-03-14T22:26:12]e000: Error 0x80070643: Failed to execute MSI package.
[1520:1578][2017-03-14T22:26:12]e000: Error 0x80070643: Failed to configure per-machine MSI package.
[1520:1578][2017-03-14T22:26:12]i319: Applied rollback package: SetupChipsetx64.msi, result: 0x80070643, restart: None
[155C:14FC][2017-03-14T22:26:12]i329: Removed package dependency provider: {FEBB7B48-CC1C-4A50-A497-FA21413F6BE9}, package: SetupChipsetx64.msi
[155C:14FC][2017-03-14T22:26:12]i351: Removing cached package: SetupChipsetx64.msi, from path: C:ProgramDataPackage Cache{FEBB7B48-CC1C-4A50-A497-FA21413F6BE9}v10.1.1.14
[155C:14FC][2017-03-14T22:26:12]i329: Removed package dependency provider: {23312E5E-F714-4F0B-97F5-4A7E2DEFE61E}, package: SetupChipsetx86.msi
[155C:14FC][2017-03-14T22:26:12]i330: Removed bundle dependency provider: {619e726e-d2b4-4e28-9568-c964fd81ee6c}
[155C:14FC][2017-03-14T22:26:12]i352: Removing cached bundle: {619e726e-d2b4-4e28-9568-c964fd81ee6c}, from path: C:ProgramDataPackage Cache{619e726e-d2b4-4e28-9568-c964fd81ee6c}
[1520:1578][2017-03-14T22:26:12]i000: ** MBA ** Apply complete. Status: ‘-2147023293’ Restart: ‘None’ Result: ‘None’
[1520:1578][2017-03-14T22:26:12]i399: Apply complete, result: 0x80070643, restart: None, ba requested restart: No
[1520:0850][2017-03-14T22:26:12]e000: ** MBA ** Неизвестная ошибка.
написал в Вопросы по лаунчеру
RE: Crash…
Помогите прошу.
У меня драйвера обновлены.
написал в Вопросы по лаунчеру
Crash…
Вообщем у меня крашнулся майнкрафт.
Вот такую ошибку выдал :
**
Bad video card drivers!
————————
Minecraft was unable to start because it failed to find an accelerated OpenGL mode.
This can usually be fixed by updating the video card drivers.
— BEGIN ERROR REPORT 7fe0271 ———
Generated 14.03.17 17:43
— System Details —
Details:
Minecraft Version: 1.5.2
Operating System: Windows 10 (x86) version 10.0
Java Version: 1.8.0_121, Oracle Corporation
Java VM Version: Java HotSpot(TM) Client VM (mixed mode), Oracle Corporation
Memory: 356784040 bytes (340 MB) / 518979584 bytes (494 MB) up to 518979584 bytes (494 MB)
JVM Flags: 3 total; -Xmx512m -Xms512m -XX:+DisableAttachMechanism
AABB Pool Size: 0 (0 bytes; 0 MB) allocated, 0 (0 bytes; 0 MB) used
Suspicious classes: FML and Forge are installed
IntCache: cache: 0, tcache: 0, allocated: 0, tallocated: 0
FML:
LWJGL: 2.4.2
OpenGL: ERROR NullPointerException: null
Is Modded: Definitely; Client brand changed to ‘fml,forge’
Type: Client (map_client.txt)
Texture Pack: faithful32.zip
Profiler Position: N/A (disabled)
Vec3 Pool Size: ERROR NullPointerException: null[failed to get system properties (java.lang.NullPointerException)]
org.lwjgl.LWJGLException: Pixel format not accelerated
at org.lwjgl.opengl.WindowsPeerInfo.nChoosePixelFormat(Native Method)
at org.lwjgl.opengl.WindowsPeerInfo.choosePixelFormat(WindowsPeerInfo.java:52)
at org.lwjgl.opengl.WindowsDisplay.createWindow(WindowsDisplay.java:185)
at org.lwjgl.opengl.Display.createWindow(Display.java:311)
at org.lwjgl.opengl.Display.create(Display.java:856)
at org.lwjgl.opengl.Display.create(Display.java:784)
at org.lwjgl.opengl.Display.create(Display.java:765)
at net.minecraft.client.Minecraft.func_71384_a(Minecraft.java:398)
at net.minecraft.client.MinecraftAppletImpl.func_71384_a(SourceFile:56)
at net.minecraft.client.Minecraft.run(Minecraft.java:733)
at java.lang.Thread.run(Unknown Source)
— END ERROR REPORT b461eff0 ———-
**
написал в Вопросы по лаунчеру
На чтение 3 мин Просмотров 16 Опубликовано 18.04.2022
Наличные деньги все больше отходят на второй план, теперь актуально использовать разные платежные системы. Их на сегодняшний день огромное количество. Большинство компаний предоставляющих подобные услуги находятся за границей, но есть и наши отечественные сервисы перевода денег, с которыми немного легче вести диалог в случае проблем с платежами.
Одной из таких проблем стало уведомление при попытке провести счет: «К сожалению, произошла ошибка при проведении платежа. Код ошибки E000. Пожалуйста, повторите платеж позже или воспользуйтесь другой картой.». Ошибку наблюдают при оплате телефона картой МТС, а также при использовании карты МИР, но сбой может встречается в любых банковских операциях.
Причины ошибки E000 при оплате картой МТС
Самое интересное в этой ситуации, что как таковой проблемы нет. Код ошибки E000 при оплате картой МТС не является следствием прерванной транзакции, она, скорее всего, была совершена. Е00 – обозначает только общую цифру кода операции “0”. А ноль на языке программных систем означает успешное проведение платежа.
При наличии кроме 0 еще каких-то цифр, уже указывает на отказ в оплате: 01, 17, 57 и т. д. Именно сейчас и нужно выяснять причину отмены транзакции. Деньги, скорее всего никуда списаны небыли, либо списание произошло, но до конечного абонента еще не дошли. Среди возможных причин также могут быть: технические проблемы в банке, неизвестная ошибка, недостаточно средств, карта не поддерживает (либо не подключена) оплату онлайн и многое другое.
Решение ситуации
- При показе ошибки E000 нужно просто проверить свой счет. Если указанная сумма была списана, то в 94% случаях все прошло хорошо. Дождитесь подтверждения о зачислении средств на указанный расчетный счет.
- Когда пришедший код только с нулями, а деньги так и не дошли до адресата, тогда следует снова проверить баланс. Деньги были списаны. Значит, банк свою часть договора выполнил и следует предъявлять претензии к платежной системе. Напишите в службу поддержки для получения разъяснений. Дополнительно свяжитесь с получателем, иногда бывают случаи удачного перечисления ему денег, а сообщения об ошибках просто все равно приходят по непонятным причинам.
- При получении 01, 02 и так далее обращайтесь напрямую в поддержку банка. Они непременно смогут помочь установить причину отказа.
Код ошибки e000 при оплате картой МТС, как было выяснено, указывает на проведение платежа. Проверьте баланс и загляните на статус покупки в личном кабинете. При любых малейших задержках пишите в службу поддержки, связаться с которой можно через mtsbank.ru.
Если у вас возникли какие либо сложности, или вы нашли новую причину появления сбоя и его решение, тогда просьба отписаться в комментариях.
|
0 / 0 / 0 Регистрация: 05.06.2020 Сообщений: 141 |
|
|
1 |
|
Произошла устраненная аппаратная ошибка21.07.2022, 18:19. Показов 3533. Ответов 44
Приветствую. Без воды сразу рассказываю. Произошла устраненная аппаратная ошибка Сообщивший компонент: ядро процессора Дополнительные сведения содержатся в подробностях этой записи. — System — Provider [ Name] Microsoft-Windows-WHEA-Logger EventID 19 Version 0 Level 3 Task 0 Opcode 0 Keywords 0x8000000000000000 — TimeCreated [ SystemTime] 2022-07-21T14:51:02.8607271Z EventRecordID 35579 — Correlation [ ActivityID] {57a25031-b53f-426e-a740-393a144de8e0} — Execution [ ProcessID] 1920 Channel System Computer WSWS9090 — Security [ UserID] S-1-5-19 — EventData ErrorSource 0 — <Event xmlns=»http://schemas.microsoft.com/win/2004/08/events/event»>
Предупреждения эти начинают появляться если частоту оперативной памяти выставлять на 3933 или 4000 Mhz. Если частота выставлена на 3866 или любая ниже этой, то никаких предупреждений не появляется. Спеки ПК : Миниатюры
0 |
|
0 / 0 / 0 Регистрация: 05.06.2020 Сообщений: 141 |
|
|
21.07.2022, 18:58 [ТС] |
2 |
|
Извиняюсь , не знаю как отредактировать. Там где указано 2000 Mhz , должно быть 4000
0 |
|
Дно пробито 4574 / 2753 / 377 Регистрация: 07.10.2020 Сообщений: 19,201 |
|
|
21.07.2022, 20:10 |
3 |
|
S1m0n толку мало с этого . Лучше полный конфиг напишите — откуда дрова брали , какие напруги и частоты стоят .
0 |
|
0 / 0 / 0 Регистрация: 05.06.2020 Сообщений: 141 |
|
|
21.07.2022, 21:25 [ТС] |
4 |
|
Wadim_Ymniy, с чего мало толка ? Дрова на что , на оперативку ? ))
0 |
|
Дно пробито 4574 / 2753 / 377 Регистрация: 07.10.2020 Сообщений: 19,201 |
|
|
21.07.2022, 21:26 |
5 |
|
А напруги может уже напишите наконец и тайминг какие ставите ?
0 |
|
0 / 0 / 0 Регистрация: 05.06.2020 Сообщений: 141 |
|
|
21.07.2022, 21:26 [ТС] |
6 |
|
Wadim_Ymniy, все дрова с оффсайтов гигабайт и амд
0 |
|
Дно пробито 4574 / 2753 / 377 Регистрация: 07.10.2020 Сообщений: 19,201 |
|
|
21.07.2022, 21:27 |
7 |
|
Там где указано 2000 Mhz , должно быть 4000 ты часом реальную частоту с эффективной не попутал ?
0 |
|
0 / 0 / 0 Регистрация: 05.06.2020 Сообщений: 141 |
|
|
21.07.2022, 21:38 [ТС] |
8 |
|
Wadim_Ymniy, включён XMP профиль. Напряжение на оперативку стоит на авто ( 1,38 ). Тайминги не трогал вообще , они тоже от XMP , сейчас не за компом , точно не помню , но вроде 16-18-18-36 CR1. Добавлено через 4 минуты
0 |
|
0 / 0 / 0 Регистрация: 05.06.2020 Сообщений: 141 |
|
|
21.07.2022, 21:41 [ТС] |
9 |
|
Вот для наглядности Миниатюры
0 |
|
4709 / 2355 / 479 Регистрация: 09.09.2017 Сообщений: 8,650 |
|
|
21.07.2022, 22:08 |
10 |
|
Вот для наглядности Тайминги для такой частоты малы.
ну потом пробовал поднимать частоту оперативки и Инфинити фабрик Увеличивать надо и тайминги. А чтобы не делать наобум, есть DRAM Calculator for Ryzen.
0 |
|
0 / 0 / 0 Регистрация: 05.06.2020 Сообщений: 141 |
|
|
21.07.2022, 22:31 [ТС] |
11 |
|
ibarg, то есть думаете это огромное количество предупреждений только лишь из за таймингов памяти ?
0 |
|
Дно пробито 4574 / 2753 / 377 Регистрация: 07.10.2020 Сообщений: 19,201 |
|
|
21.07.2022, 22:34 |
12 |
|
Да реально — тайминги подозрительно низкие : если это не ОЗУ от Г.скилл за овер 30+ тысяч , то фига с два они на 18 таймингах на 4000 работать будут и не факт что КП процессора сможет .
0 |
|
0 / 0 / 0 Регистрация: 05.06.2020 Сообщений: 141 |
|
|
21.07.2022, 22:47 [ТС] |
13 |
|
Wadim_Ymniy, потому что это крушиал баллистикс на чипах micron e-die. Эти планки могут и на 4400 работать с таймингами ниже моих
0 |
|
4709 / 2355 / 479 Регистрация: 09.09.2017 Сообщений: 8,650 |
|
|
21.07.2022, 22:54 |
14 |
|
огромное количество предупреждений только лишь из за таймингов памяти ? Может быть. Может и контроллер памяти дает сбои из-за высокой частоты. Может по совокупности. Добавлено через 6 минут
Эти планки могут и на 4400 работать с таймингами ниже моих Могут, но только с делителем частоты контроллера памяти.
0 |
|
0 / 0 / 0 Регистрация: 05.06.2020 Сообщений: 141 |
|
|
21.07.2022, 22:58 [ТС] |
15 |
|
ibarg, только с делителем частоты контроллера памяти. А в чем разница , если не сложно объяснить ?
0 |
|
Дно пробито 4574 / 2753 / 377 Регистрация: 07.10.2020 Сообщений: 19,201 |
|
|
21.07.2022, 23:43 |
17 |
|
потому что это крушиал баллистикс на чипах micron e-die. Эти планки могут и на 4400 работать не факт что мать/процц даже с делителем справятся — тут кому как везёт
0 |
|
0 / 0 / 0 Регистрация: 05.06.2020 Сообщений: 141 |
|
|
22.07.2022, 00:32 [ТС] |
18 |
|
ibarg, Wadim_Ymniy, у меня XMP профиль на 3600 MHz. Если я допустим хочу частоты выше , чем XMP и с помощью Dram калькулятора определю нужные тайминги. Вопрос !! Нужно ли отключать XMP и выставлять частоты , тайминги или неважно включён он будет или нет ?
0 |
|
Дно пробито 4574 / 2753 / 377 Регистрация: 07.10.2020 Сообщений: 19,201 |
|
|
22.07.2022, 00:48 |
19 |
|
ХМП это предустановка — а тебе нужен кастмный рофиль .
0 |
|
0 / 0 / 0 Регистрация: 05.06.2020 Сообщений: 141 |
|
|
22.07.2022, 00:56 [ТС] |
20 |
|
Wadim_Ymniy, не факт что мать/процц даже с делителем справятся мать , кстати , поддерживает до 4400 , ну а райзенам как известно всем нужна высокая частота как минимум 3800. Добавлено через 2 минуты ХМП это предустановка — а тебе нужен кастмный рофиль . я понимаю что такое XMP. Но играть с частотой и таймингами можно и с включённым профилем XMP и с выключенным , по крайне мере на моей материнке. Так вот и спрашиваю есть разница , если он будет вкл / откл , когда я хочу выставить частоты выше ?!
0 |
Ошибка E000 в лазерных принтерах и МФУ Canon означает неисправность узла термозакрепления. Эта ошибка появляется, когда при подаче напряжения на термоэлемент, датчик температуры не догревается до нужной температуры. Обычно это означает выход из строя термоэлемента. Но иногда встречаются нюансы. О них мы и поговорим.
И так, перед нами Canon MF4410
с ошибкой E000
Дело в том, что, в последнее время, довольно часто мне в ремонт попадают устройства с ошибкой E000 в которых термоэлемент вполне исправен, а проблема оказывается с блоком питания Canon. При том, это касается не только относительно новых устройств, но и устройств постарше, к примеру, LBP2900. На термоэлемент с блока питания подается 220 вольт переменного напряжения. Что бы выяснить, рабочий ли блок питания, необходимо мультиметром проверить, подается ли на разъем подключения термоэлемента напряжение. Но сначала необходимо добраться до этого разъема.
И так, приступим. Откручиваем болт сзади устройства, со стороны разъема USB.
Сзади и снизу местонахождение защелок боковой крышки показано треугольниками,
а сверху черточками.
После снятия боковой крышки, отсоединяем все шлейфы и кабели от платы управления
Откручиваем сзади болт, который находится над разъемом USB.
Откручиваем все болты крепящие плату управления и снимаем ее.
Для того, что бы снять пластмассовое крепление шлейфов, необходимо поднять вверх защелку и сдвинуть крепление вправо.
Снимаем металлический каркас, на котором крепилась плата управления. Для этого откручиваем все болты, крепящие каркас.
Вот мы и добрались до разъема питания термоэлемента. Подключаем плату управления в подвешенном состоянии, следя за тем, что бы ничего не замкнуть.Включаем устройство и замеряем напряжение на разъеме подключения термоэлемента. Хочу заметить, что у меня был случай, когда с отключенным термоэлементом напряжение присутствовало, а с подключенным, под нагрузкой, напряжения не было. Так что рекомендую замерять напряжение с подключенным термоэлементом.
Схема управления подачи питания на термоэлемент во всех устройствах Canon практически идентична. Неисправны могут быть несколько элементов вместе или по отдельности:
1. Подгорели контакты реле 1. Проверить просто — необходимо подать около 20 вольт с любого блока питания и прозвонить контакты, которые должны замкнуться.
2. Вышел из строя транзистор 2.
3. Проблема в оптроне 3. Проверить довольно сложно, лучше заменить.
4. Пробитый диод 4. Для проверки выпаять и прозвонить.
При данном дефекте выхода из строя других элементов я не встречал. Надеюсь статья вам поможет. Удачи.


