Dorma es200 коды ошибок

Error codes (fault codes) reference of ES200 automatic door malfunctions (Dorma ES200 applicable).


Dorma ES 200 Error CodesERROR CODES (FAULT CODES) REFERENCE – ES200

Error Code 0 – No error
Error Code 1 – Obstruction
Error Code 2 – Lock error
Error Code 3 – Program switch malfunction
Error Code 4 – Light barrier / safety sensor error
Error Code 5 – Incremental encoder malfunction
Error Code 6 – Backup battery (accumulator) failure
Error Code 7 – System error
Error Code 8 – Emergency Stop malfunction
Error Code 9 – Learning cycle parameter error
Error Code A – Motor malfunction
Error Code c – Force test failure
Error Code d – Over current at motor
Error Code F – DCW error
Error Code L – Relay test failure

General Measures:

  1. Set program switch to AUTOMATIC – CLOSE – AUTOMATIC.
  2. Power off, wait for 20 seconds, power back on.
  3. Run automatic learning cycle

Above measures are general solutions, real cause can be various, need carefully checking on door panels and rail, make sure the movement is smooth, and all wire connections are steady, especially good contact at the control terminals.

Reference:

  • Restore ES200 original factory settings.

Error codes (fault codes) reference of ES200 automatic door malfunctions (Dorma ES200 applicable).


Dorma ES 200 Error CodesERROR CODES (FAULT CODES) REFERENCE – ES200

Error Code 0 – No error
Error Code 1 – Obstruction
Error Code 2 – Lock error
Error Code 3 – Program switch malfunction
Error Code 4 – Light barrier / safety sensor error
Error Code 5 – Incremental encoder malfunction
Error Code 6 – Backup battery (accumulator) failure
Error Code 7 – System error
Error Code 8 – Emergency Stop malfunction
Error Code 9 – Learning cycle parameter error
Error Code A – Motor malfunction
Error Code c – Force test failure
Error Code d – Over current at motor
Error Code F – DCW error
Error Code L – Relay test failure

General Measures:

  1. Set program switch to AUTOMATIC – CLOSE – AUTOMATIC.
  2. Power off, wait for 20 seconds, power back on.
  3. Run automatic learning cycle

Above measures are general solutions, real cause can be various, need carefully checking on door panels and rail, make sure the movement is smooth, and all wire connections are steady, especially good contact at the control terminals.

Reference:

  • Restore ES200 original factory settings.

Dorma ES 200 Manual

  • Bookmarks

Quick Links

ES 200

Sliding door operator

Related Manuals for Dorma ES 200

Summary of Contents for Dorma ES 200

  • Page 1
    ES 200 — Sliding door operator…
  • Page 2
    Delivery formats for the implementation of new Particularly impressive is the application on the basis of just The ES 200 is available as a prefabricated MiniDriveUnit, ideas and individual concepts in a few components. The system component kit, as a complete,…
  • Page 3
    24 V output for external accessory Opening and closing force, max. 150 N Read-out error memory with error codes Opening speed bus interface (Protokoll DORMA Connect and Work) 10 – 70 cm/s ® (incremental setting) Rechargeable battery pack for emergency operation Closing speed 10 –…
  • Page 4
    ES 200 SLIDING DOOR OPERATOR Pulley with integrated locking device and belt tensioning device Profiles for corridor installation, 100 mm Profiles for wall installation, 100 mm Our profiles for installation heights of 100 mm and 150 mm, which are suitable for both…
  • Page 5
    ES 200 SLIDING DOOR OPERATOR MiniDriveUnit At the core of the ES 200 Components The prefabricated MiniDriveUnit 1 MiniDriveUnit 10 Pulley (locking device) has been industrially tested with 2 Power supply unit 11 Service cover bracket all the requisite electrical and…
  • Page 6
    ES 200 SLIDING DOOR OPERATOR THE PROFESSIONAL OPERATOR FOR INDIVIDUAL DOOR DESIGN — Door variants with ES 200, 100 mm installation height and special ”profile“ version DORMA PowerDrive System for particularly punchy performance The door variants on this page are shown as corridor installation with aluminium girder (LM).
  • Page 7
    * Safety sensors to monitor the secondary closing edges in accordance with DIN 18650 and EN 16005 **Safety sensors to monitor the main closing edge in accordance with DIN 18650 and EN 16005 PROGRAM SWITCHES — A program switch from DORMA’s The corresponding 3-position They offer various options, from Up to 5 different functions:…
  • Page 8: Push Button

    ES 200 SYSTEM ACCESSORIES SWITCHES — Designation Specification Installation system Order No. On/Off switch White, aluminium, flush-mounting, 80 x 80 mm Gira S-Color 19135403150 Radar switch „MAGIC SWITCH”, proximity-type radar switch responds to movement, for flush-mounting, 80 x 80 mm…

  • Page 9
    ES 200 SYSTEM ACCESSORIES EMERGENCY PUSHBUTTONS — Designation Specification Installation system Order No. Designed to interrupt the automatic movement of the door, emergency pushbutton (function: Emergency Off) for automatic door operators, manufactured to ZH 1/494 or BGR 232, DIN 18650 and EN 16005, red knob with yellow centre insert, max.
  • Page 10: Motion Detectors

    ES 200 SYSTEM ACCESSORIES MOTION DETECTORS — Motion detectors Designation Specification Colour Order No. Prosecure Full-automatic access on pulse activation; Easy Motion adjustable inclination angle, Mono inclined field of view and field size, LED status indicator, not in accordance black…

  • Page 11
    ES 200 SYSTEM ACCESSORIES TRIMS AND BOXES FOR SURFACE-MOUNTED PUSHBUTTONS AND SWITCHES — Dimensions Designation Specification Installation system Order No. in mm (W x H x D) System 55 Cover frame (Programm STA) FR-S55 1 Single-type trim, Standard 55, white 80.7 x 80.7 System 55…
  • Page 12
    DORMA Deutschland GmbH DORMA Platz 1 58256 ENNEPETAL GERMANY Phone +49 2333 793-0 +49 2333 793-4950 www.dorma.com…

Dorma ES 200 Manual

  • Bookmarks

Quick Links

ES 200

Sliding door operator

Related Manuals for Dorma ES 200

Summary of Contents for Dorma ES 200

  • Page 1
    ES 200 — Sliding door operator…
  • Page 2
    Delivery formats for the implementation of new Particularly impressive is the application on the basis of just The ES 200 is available as a prefabricated MiniDriveUnit, ideas and individual concepts in a few components. The system component kit, as a complete,…
  • Page 3
    24 V output for external accessory Opening and closing force, max. 150 N Read-out error memory with error codes Opening speed bus interface (Protokoll DORMA Connect and Work) 10 – 70 cm/s ® (incremental setting) Rechargeable battery pack for emergency operation Closing speed 10 –…
  • Page 4
    ES 200 SLIDING DOOR OPERATOR Pulley with integrated locking device and belt tensioning device Profiles for corridor installation, 100 mm Profiles for wall installation, 100 mm Our profiles for installation heights of 100 mm and 150 mm, which are suitable for both…
  • Page 5
    ES 200 SLIDING DOOR OPERATOR MiniDriveUnit At the core of the ES 200 Components The prefabricated MiniDriveUnit 1 MiniDriveUnit 10 Pulley (locking device) has been industrially tested with 2 Power supply unit 11 Service cover bracket all the requisite electrical and…
  • Page 6
    ES 200 SLIDING DOOR OPERATOR THE PROFESSIONAL OPERATOR FOR INDIVIDUAL DOOR DESIGN — Door variants with ES 200, 100 mm installation height and special ”profile“ version DORMA PowerDrive System for particularly punchy performance The door variants on this page are shown as corridor installation with aluminium girder (LM).
  • Page 7
    * Safety sensors to monitor the secondary closing edges in accordance with DIN 18650 and EN 16005 **Safety sensors to monitor the main closing edge in accordance with DIN 18650 and EN 16005 PROGRAM SWITCHES — A program switch from DORMA’s The corresponding 3-position They offer various options, from Up to 5 different functions:…
  • Page 8: Push Button

    ES 200 SYSTEM ACCESSORIES SWITCHES — Designation Specification Installation system Order No. On/Off switch White, aluminium, flush-mounting, 80 x 80 mm Gira S-Color 19135403150 Radar switch „MAGIC SWITCH”, proximity-type radar switch responds to movement, for flush-mounting, 80 x 80 mm…

  • Page 9
    ES 200 SYSTEM ACCESSORIES EMERGENCY PUSHBUTTONS — Designation Specification Installation system Order No. Designed to interrupt the automatic movement of the door, emergency pushbutton (function: Emergency Off) for automatic door operators, manufactured to ZH 1/494 or BGR 232, DIN 18650 and EN 16005, red knob with yellow centre insert, max.
  • Page 10: Motion Detectors

    ES 200 SYSTEM ACCESSORIES MOTION DETECTORS — Motion detectors Designation Specification Colour Order No. Prosecure Full-automatic access on pulse activation; Easy Motion adjustable inclination angle, Mono inclined field of view and field size, LED status indicator, not in accordance black…

  • Page 11
    ES 200 SYSTEM ACCESSORIES TRIMS AND BOXES FOR SURFACE-MOUNTED PUSHBUTTONS AND SWITCHES — Dimensions Designation Specification Installation system Order No. in mm (W x H x D) System 55 Cover frame (Programm STA) FR-S55 1 Single-type trim, Standard 55, white 80.7 x 80.7 System 55…
  • Page 12
    DORMA Deutschland GmbH DORMA Platz 1 58256 ENNEPETAL GERMANY Phone +49 2333 793-0 +49 2333 793-4950 www.dorma.com…
  • #1

Добрый день,подскажите что это за ошибка,и что с ней делать,скажу сразу диагностики и тестера у нас в городе нет,и нормальных специалистов.

  • -5323724577890746342_121.jpg

    -5323724577890746342_121.jpg

    123.7 KB

    · Просмотры: 15

  • #2

Сам не встречался. Инструкция гласит:

1.jpg

  • #3

Сам не встречался. Инструкция гласит:

Посмотреть вложение 37766

дело в том что никакие манипуляции с ней не делали,ЭУП во всем городе нет,был перепад напряжения по всему зданию,после чего она перестала работать,прослужила с 2010 года.Может есть какие-то действия чтобы без тестера обновить её.

-=BVS=-

-=BVS=-

Квалифицированный специалист
  • #4

дело в том что никакие манипуляции с ней не делали,ЭУП во всем городе нет,был перепад напряжения по всему зданию,после чего она перестала работать,прослужила с 2010 года.Может есть какие-то действия чтобы без тестера обновить её.

Прочитайте внимательно нижнюю строчку. Ничего делать чтобы появилась эта ошибка не требуется, достаточно неудачно обесточить дверь. Теперь контроллер не знает ничего о размерах и типе двери и требуется полностью настроить его по мануалу как с завода.

  • #5

Последнее редактирование: 4 Окт 2022

  • #6

Прочитайте внимательно нижнюю строчку. Ничего делать чтобы появилась эта ошибка не требуется, достаточно неудачно обесточить дверь. Теперь контроллер не знает ничего о размерах и типе двери и требуется полностью настроить его по мануалу как с заво

  • #7

спасибо большое всем по мануалу сделали как вы все сказали.и о чудо заработало.так бы ушли в минус на 250 к руб.на новую дверь.

-=BVS=-

-=BVS=-

Квалифицированный специалист
  • #8

спасибо большое всем по мануалу сделали как вы все сказали.и о чудо заработало.так бы ушли в минус на 250 к руб.на новую дверь.

Удачи тебе брат. У вас там проблем хватает и без дверей.

  • #1

Добрый день,подскажите что это за ошибка,и что с ней делать,скажу сразу диагностики и тестера у нас в городе нет,и нормальных специалистов.

  • -5323724577890746342_121.jpg

    -5323724577890746342_121.jpg

    123.7 KB

    · Просмотры: 24

  • #2

Сам не встречался. Инструкция гласит:

1.jpg

  • #3

Сам не встречался. Инструкция гласит:

Посмотреть вложение 37766

дело в том что никакие манипуляции с ней не делали,ЭУП во всем городе нет,был перепад напряжения по всему зданию,после чего она перестала работать,прослужила с 2010 года.Может есть какие-то действия чтобы без тестера обновить её.

-=BVS=-

-=BVS=-

Квалифицированный специалист


  • #4

дело в том что никакие манипуляции с ней не делали,ЭУП во всем городе нет,был перепад напряжения по всему зданию,после чего она перестала работать,прослужила с 2010 года.Может есть какие-то действия чтобы без тестера обновить её.

Прочитайте внимательно нижнюю строчку. Ничего делать чтобы появилась эта ошибка не требуется, достаточно неудачно обесточить дверь. Теперь контроллер не знает ничего о размерах и типе двери и требуется полностью настроить его по мануалу как с завода.

  • #5

Последнее редактирование: 4 Окт 2022

  • #6

Прочитайте внимательно нижнюю строчку. Ничего делать чтобы появилась эта ошибка не требуется, достаточно неудачно обесточить дверь. Теперь контроллер не знает ничего о размерах и типе двери и требуется полностью настроить его по мануалу как с заво

  • #7

спасибо большое всем по мануалу сделали как вы все сказали.и о чудо заработало.так бы ушли в минус на 250 к руб.на новую дверь.

-=BVS=-

-=BVS=-

Квалифицированный специалист


  • #8

спасибо большое всем по мануалу сделали как вы все сказали.и о чудо заработало.так бы ушли в минус на 250 к руб.на новую дверь.

Удачи тебе брат. У вас там проблем хватает и без дверей.

Dorma ES 200 Manual

  • Bookmarks

Quick Links

ES 200

Sliding door operator

loading

Related Manuals for Dorma ES 200

Summary of Contents for Dorma ES 200

  • Page 1
    ES 200 — Sliding door operator…
  • Page 2
    Delivery formats for the implementation of new Particularly impressive is the application on the basis of just The ES 200 is available as a prefabricated MiniDriveUnit, ideas and individual concepts in a few components. The system component kit, as a complete,…
  • Page 3
    24 V output for external accessory Opening and closing force, max. 150 N Read-out error memory with error codes Opening speed bus interface (Protokoll DORMA Connect and Work) 10 – 70 cm/s ® (incremental setting) Rechargeable battery pack for emergency operation Closing speed 10 –…
  • Page 4
    ES 200 SLIDING DOOR OPERATOR Pulley with integrated locking device and belt tensioning device Profiles for corridor installation, 100 mm Profiles for wall installation, 100 mm Our profiles for installation heights of 100 mm and 150 mm, which are suitable for both…
  • Page 5
    ES 200 SLIDING DOOR OPERATOR MiniDriveUnit At the core of the ES 200 Components The prefabricated MiniDriveUnit 1 MiniDriveUnit 10 Pulley (locking device) has been industrially tested with 2 Power supply unit 11 Service cover bracket all the requisite electrical and…
  • Page 6
    ES 200 SLIDING DOOR OPERATOR THE PROFESSIONAL OPERATOR FOR INDIVIDUAL DOOR DESIGN — Door variants with ES 200, 100 mm installation height and special ”profile“ version DORMA PowerDrive System for particularly punchy performance The door variants on this page are shown as corridor installation with aluminium girder (LM).
  • Page 7
    * Safety sensors to monitor the secondary closing edges in accordance with DIN 18650 and EN 16005 **Safety sensors to monitor the main closing edge in accordance with DIN 18650 and EN 16005 PROGRAM SWITCHES — A program switch from DORMA’s The corresponding 3-position They offer various options, from Up to 5 different functions:…
  • Page 8: Push Button

    ES 200 SYSTEM ACCESSORIES SWITCHES — Designation Specification Installation system Order No. On/Off switch White, aluminium, flush-mounting, 80 x 80 mm Gira S-Color 19135403150 Radar switch „MAGIC SWITCH”, proximity-type radar switch responds to movement, for flush-mounting, 80 x 80 mm…

  • Page 9
    ES 200 SYSTEM ACCESSORIES EMERGENCY PUSHBUTTONS — Designation Specification Installation system Order No. Designed to interrupt the automatic movement of the door, emergency pushbutton (function: Emergency Off) for automatic door operators, manufactured to ZH 1/494 or BGR 232, DIN 18650 and EN 16005, red knob with yellow centre insert, max.
  • Page 10: Motion Detectors

    ES 200 SYSTEM ACCESSORIES MOTION DETECTORS — Motion detectors Designation Specification Colour Order No. Prosecure Full-automatic access on pulse activation; Easy Motion adjustable inclination angle, Mono inclined field of view and field size, LED status indicator, not in accordance black…

  • Page 11
    ES 200 SYSTEM ACCESSORIES TRIMS AND BOXES FOR SURFACE-MOUNTED PUSHBUTTONS AND SWITCHES — Dimensions Designation Specification Installation system Order No. in mm (W x H x D) System 55 Cover frame (Programm STA) FR-S55 1 Single-type trim, Standard 55, white 80.7 x 80.7 System 55…
  • Page 12
    DORMA Deutschland GmbH DORMA Platz 1 58256 ENNEPETAL GERMANY Phone +49 2333 793-0 +49 2333 793-4950 www.dorma.com…

ED100 / ED250

Error message memory

There are ten error message memory locations, «E0» through

To access error messages, briefly press

messages contained in E0 to E9 memory.

Latest error message is always stored in error message memory

As soon as another error occurs, or after existing «E0» error

has been reset, the former «latest» error in «E0» will be moved

to error message memory location «E1».

A maximum of nine errors can therefore be stored in «E1»

through «E9» memory locations. Identical error messages

which occur one after the other are not saved again.

If error E 15 occurs, and it is the first error, it will be stored in

the current (latest) error memory location «E0».

By briefly press

, the first error to be displayed will be E 15.

If a second error occurs before first error has been «Reset «

E 04 has occured, as an example.

E 15 will be moved to error memory location «E1», and E 04

will be stored in current (latest) memory location «E0».

By briefly pressing

to call up error messages memory

locations E0, the first message to be displayed will be

E 04 (the latest error), briefly pressing

the next message, E 15.

A maximum of nine errors can therefore be saved in E1 – E9

DORMA AUTOMATICES, Inc.

to display error

again will display

924 Sherwood Drive

Lake Bluff, IL 60044

Operator unit LED status

ON – Indicates internal 24VDC power on.

OFF – Indicates internal 24VDC power off.

Maintenance interval indicator. When illuminated, it is an

indication that operator system should be serviced.

Maintenance interval is adjustable by DORMA service.

Blinking codes are used to indicate «ln __» information or

certain error codes «E __».

Details on each display code, or LED status, can be found in

the troubleshooting chart starting on the next page.

Flashing 2 times E 02

Flashing 4 times E 04

Flashing 5 times E 25

Flashing 5 times E 51, E 52, E 53

Flashing 6 times E 62

Flashing 6 times E 63

Flashing 7 times E 71

Flashing 7 times E 72

Flashing 7 times E 73

Flashing 12 times E 12

Flashing 13 times E 13

Flashing 15 times E 15

Subject to change without notice

Control unit has detected

error – Emergency mode

has been activated

Hold-open device was

Locking device error

Safety sensor test error

SVP Power Reserve

(PR) DCW module test

Second system has

incompatible with double

door system operation

System error 1 (test)

second shutdown option

System error 2 (test)

current measuring circuit

System error 3 (test)

Fautly learning cycle

Автоматические двери дорма не работают

АВТОМАТИЧЕСКИЕ СИСТЕМЫ BESAM АВТОМАТИЧЕСКИЕ СИСТЕМЫ DORMA АВТОМАТИЧЕСКИЕ СИСТЕМЫ DITEC АВТОМАТИЧЕСКИЕ СИСТЕМЫ FAAC АВТОМАТИЧЕСКИЕ СИСТЕМЫ GEZE АВТОМАТИЧЕСКИЕ СИСТЕМЫ GU АВТОМАТИЧЕСКИЕ СИСТЕМЫ KABA АВТОМАТИЧЕСКИЕ СИСТЕМЫ PORTALP АВТОМАТИЧЕСКИЕ СИСТЕМЫ TORMAX

ЧАСТО ЗАДАВАЕМЫЕ ВОПРОСЫ О РАБОТЕ ДВЕРЕЙ

В этом разделе мы собрали частые вопросы по неисправности раздвижных автоматических дверей и постарались дать понятные и развернутые ответы. Если по каким-то причинам вы не нашли ответ на свой вопрос, то в этом случае предлагаем решить его по телефону или заявке на нашем сайте. Желаем надежной работы для ваших автоматических дверей.

У нас не работает привод автоматической двери.

– Необходимо проверить, какой режим установлен на пульте управления. Проверить, поступает ли питание на привод. Убедиться, что нет механических препятствий для движения створок. Провести перезапуск (тест) привода. – Постараться по звуковым, световым сигналам на дисплее и т.д. определить характер дефекта.

Автоматическая дверь открывается и не закрывается.

– Определить, какой из трех факторов не дает закрыться двери ( активированные датчики движения, неработающие световые барьеры, разряд аккумуляторов, отсутствие электрического питания).

Дверь не открывается при подходе с одной из сторон или открывается, не завершив цикл полного закрытия.

– Требуется регулировка, ремонт, замена одного из радаров.

Дверь живет своей жизнью, не выполняет штатные команды.

– Попробуйте перезапустить привод, отключив и включив питание.

Дверь несколько раз открывается, а затем останавливается.

– Похоже, что это дефект двигателя или энкодера.

Автоматическое открывание и закрывание дверей происходит очень медленно.

– Возможно, это тестовое движения и процессор не пропускает в работу изношенный двигатель.

– Не работают световые барьеры.

Привод автоматических дверей шумит, издает подозрительные звуки.

– Определить их источник, что шумит: мотор-редуктор, каретки, створки, приводной ремень или что-то иное? Для этого потребуется отключить питание привода и подвигать створки руками.

Створки автоматической двери ударяют людей.

– Неправильно организован проход людей, неправильно настроены, подобраны датчики движения.

Автоматическая дверь начала останавливаться несколько раз в день, но при перезапуске продолжает работать.

– Неисправность, износ щеток в моторе-редукторе, износ подшипников червячных колес в мотор-редукторе.

– В некоторых случаях это связано с сильными сквозняками. Выявить характер проблемы можно после диагностики дверей.

Как отключить привод?

– Обесточить автоматический привод.

– Осуществить эти же операции с помощью панели управления (выполняется на некоторых приводах).

Есть ли у Вас опыт работы с азиатскими производителями?

Да, подробнее об этом Вы можете почитать здесь.

Привод автоматических раздвижных дверей Dorma ES 90-100

Большое распространение получили приводы автоматических раздвижных дверей производства Dorma. Они одни из первых появились у нас в стране. Поставки сопровождались документацией по сборке автоматического привода, что позволяло находить поломки в максимально сжатые сроки. За прошедшие годы тысячи раздвижных дверей оснащены приводами Dorma и имеют значительный ресурс эксплуатации. Первые признаки сбоев в работе проявляются не сразу, двери несколько лет могут работать отлично. Но постепенно износ дает о себе знать. Двери иногда останавливаются, но, проведя самостоятельно тест, восстанавливают свою работу.

Автоматическая дверь дорма es200 коды ошибок

Точная диагностика поломок возможна только с помощью программатора. Перечислим часто встречающиеся:

Следует знать, что эти механизмы давно сняты с производства и любые запчасти к ним стоят дорого. Производители приводов стремятся к тому, чтобы потребители покупали новые изделия. В этом случае мы рекомендуем применять аналоги при ремонте.

Ремонт автоматических дверей – износ деталей

Отдельные детали привода вырабатываются раньше, чем другие. В первую очередь это двигатель и ролики в каретках. В приводе автоматических раздвижных дверей Dorma применен двигатель серии GR 63-25. Ему нетрудно подобрать замену. Стоимость нового двигателя составит 30% от оригинала, хотя ресурс у них одинаковый. В некоторых случаях возможен ремонт самого двигателя, когда проводят замену износившихся частей. Стоимость такого ремонта не превышает нескольких тысяч рублей. После проведенной замены привод работает в штатном режиме. Параметры установленного оборудования соответствуют оригиналу. Часто видя сбои в работе, остановку привода, потребитель проводит обновление программы. Результат всегда один: установленные двери автоматические не преодолевают тест и останавливаются. Кажется, что привод умер навсегда. На самом деле требуется только замена или ремонт электрического двигателя.

Решение проблем с роликами

Подобное происходит при повышенном износе роликов в каретках механизма. Створки начинают “попрыгивать”, что в итоге приводит к скачкам тока в цепи. Контроллер определяет эти перегрузки и проводит бесконечные тесты привода. Радикальным решением проблемы является замена роликов в каретках. Если замена не проводится вовремя, то происходит повышенный износ треков, по которым катаются ролики. Особенно это бывает часто, если створки раздвижных дверей достаточно тяжелые.

В этом случае мы можем оказать услугу по ремонту (выравниванию) трека. Возможно также профилирование роликов, повторное их протачивание с устранением дефектов, полученных при эксплуатации. При этом нет необходимости по замене балки.

При проведении ремонта автоматических дверей

В магазине или супермаркете при повышенном весе створок нет необходимости менять привод целиком. Достаточно установить двигатель повышенной мощности Dorma ES90-100 GR 63-55. Возможность установки такого двигателя предусмотрено штатно.

Автоматические двери DORMA

Автоматические двери DORMA ES 75

Эти автоматические двери DORMA установлены в медицинском центре г. Краснодара. Одностворчатые, с радарами сенсорами управляемые ладонью. СТОП кнопка в этой версии не нужна. Вместо нее поставили перемычку. Управление режимами дверей сенсорное на три режима. Вполне оправданное решение без лишних опций. Установка автоматических дверей произведена за 7 часов.

Автоматические двери DORMA могут быть разной комплектации и для разных целей. Двери DORMA с приводом ES 75, ES 200, ES 200 easy самые популярные в России. Есть запчасти к ним. Сервисное обслуживание автоматических дверей DORMA обеспечит долгую работоспособность. Если сравнить двери DORMA с остальными производителями, то они выделяются эстетикой и простотой обслуживания. Направляющие створок легко меняются. Оптические фотоэлементы определяются с первого раза и без дополнительных устройств. В коробе доступны моторедуктор и блок управления. Обучение автоматических дверей DORMA запускается одной кнопкой. Управление режимом двери интуитивно понятно. На что обратить внимание при установке дверей DORMA? На наличие монтажной пластины на которую вешается короб привода. Это дает жесткость конструкции и регулировка створок становится доступнее. По моему мнению проблему часто создает СТОП кнопка. Дверь внезапно перестает работать если часто пользоваться СТОП кнопкой. Не надежна она. Когда вызывают на ремонт двери DORMA в блоке управления я отключаю СТОП кнопку и ставлю перемычку. Дверь работает исправно? Это СТОП кнопка неисправна. Если так же неисправна, то это уже ключ блок переключения режимов двери. Вот некоторые лайф-хаки. Автоматические двери DORMA самые простые в ремонте и эксплуатации. В случае проблем с дверями DORMA звонтие!

Ремонт всех типов автоматических дверей

Во многих промышленных зданиях (магазины, больницы, торговые центры, государственные учреждения) устанавливают прочные автоматические двери, которые являются не только удобными, но и экономически выгодными (экономия электроэнергии и тепла). Обычно такие двери работают в интенсивном режиме, поэтому постоянно нуждаются в сервисном обслуживании, замене подвижных деталей, выполнении ремонтных работ. Доверить такие работы лучше всего профессиональным специалистам. Наша компания уже ни один год успешно выполняет сервисное обслуживание и ремонт автоматических дверей. При поломке вам достаточно позвонить нашему специалисту, который в самый кротчайший срок приедет к вам, проведя тщательную диагностику, выполнив ремонт прямо на месте. Если в ходе ремонта выяснится, что необходима замена сложной детали, которая не всегда есть в наличии, то мы её находим, закупаем и устанавливаем.

Компания DOORK — SHOP . RU выполняет ремонт разных автоматических дверей. Мы выполняем не только ремонтные работы. У нас вы можете приобрести по доступной цене, раздвижные и распашные автоматически раскрываемые двери.

По своим техническим показателям автоматические двери – это сложный механизм, который периодически нуждается в правильном сервисном обслуживании и выполнении ремонтных работ. От этого зависит качество работы дверей и их долговечность (износ привода, незначительные механические повреждения, перепады подачи электроэнергии). Ко всему нужно быть готовым и вовремя всё предусмотреть.

Компания по сервисному обслуживанию DOORK — SHOP . RU выполняет не только ремонт и постгарантийное и сервисное обслуживании, но и занимается продажей запчастей. Мы уже на протяжении 10 лет успешно работаем в данной сфере обслуживании. Благодаря накопленному опыту, наши специалисты готовы устранить поломки любой сложности.

Выполняя периодическое обслуживание дверей автоматического типа, вы страхуете себя от сложных непредвиденных дорогостоящих поломок. Для каждого клиента мы прорабатываем индивидуальный подход, специалисты разрабатывают график сервисного обслуживания и выполнение планового ремонта. Мы заботимся о каждом клиенте.

На данный момент на нашем сервисном обслуживании находится множество организаций: АЗС BP , АЗС Лукойл, Роснефть, Астра, Сбербанк РФ, Сеть АЗС «ГАЗПРОМНЕФТЬ», ИКЕА, Береста Палас, а также ТЦ «Город», «Роза Хутор», сеть ТЦ «Парк Хаус» и другие.

Какие двери мы рекомендуем?

Наши специалисты выполняют ремонт большинства современных дверей автоматического типа:

— ремонт и обслуживание раздвижных дверей;

— ремонт и обслуживание распашных дверей;

— ремонт и обслуживание карусельных дверей;

Мы проводим ремонт и обслуживания дверей автоматического типа ведущих производителей;

— ремонт дверей автоматического типа компании DORMA, GEZE, G-U, ДорХан;

Наша компания гарантирует:

— качественно выполненную работу, сделанную в сроки;

— индивидуальность работы над каждым заказом;

— быстрота и качество;

Ремонт автоматических дверей (цена указана от)

Объем и полную стоимость уточняйте у менеджера.

Сервис центр по обслуживанию и ремонту автоматических дверей

Сервисный центр компаниии Гласис-Автоматик производим ремонт и техническое обслуживание автоматических дверей следующих производителей: GLASIS, FAAC, DORMA, GEZE, TORMAX, DITEC, CAME, LABEL, BFT, BESAM, MANUSA, NABCO, RECORD, KABA и др.

Мы предлагаем Вашему вниманию несколько видов технического обслуживания автоматических дверей:

Сервисное обслуживание автоматических дверей включает в себя:

Перечень работ по техническому обслуживанию

1. Автоматические двери

1.1.1
Акустический и визуальный контроль работы узлов автоматической двери
1 раз в 3 месяца

1.1.2
Проверка состояния направляющих оператора (степень износа)
-//-

1.1.3
Проверка состояния роликов кареток на наличие износа и механических повреждений рабочих поверхностей
-//-

1.1.4
Промывка Уайт спиритом и очистка рабочих поверхностей направляющих оператора и роликов от пыли и грязи
-//-

1.1.5
Очистка оператора и механизма а/д от пыли и грязи, смазка направляющих силиконовой смазкой
-//-

1.1.6
Протяжка болтовых и винтовых соединений механизма. Устранение возникших в ходе эксплуатации люфтов
-//-

1.1.7
Регулировка положения подвижных створок а/д
-//-

1.1.8
Проверка и регулировка натяжения ходового ремня
-//-

1.1.9
Регулировка электромеханического замка
-//-

1.2.1
Проверка состояния кабелей и протяжка клеммных соединений
1 раз в 3 месяца

1.2.2
Регулировка параметров электронного блока управления
-//-

1.2.3
Регулировка детекторов движения
-//-

1.2.4
Проверка правильной работы селектора режимов
-//-

1.2.5
Проверка работы системы во всех предусмотренных режимах
-//-

2. Автоматический шлагбаум

2.1
Акустический и визуальный контроль работы узлов автоматического шлагбаума
1 раз в 6 месяцев

2.2
Проверка корпуса и стрелы шлагбаума на наличие механических повреждений
-//-

2.3
Промывка Уайт спиритом подвижных элементов механизма и смазка рабочих поверхностей тяги коромысла и выходного вала редуктора консистентной смазкой (ЦИАТИМ 201)
-//-

2.4
Протяжка болтовых и винтовых соединений
-//-

2.5
Регулировка натяжения компенсационной пружины
-//-

2.6
Регулировка концевых выключателей
-//-

2.7
Проверка положения стрелы в крайних точках и регулировка упоров коромысла и стрелы
-//-

2.8
Проверка утечки смазки из корпуса редуктора и подтяжка креплений редуктора
-//-

2.9
Проверка состояния кабелей и протяжка клеммных соединений
-//-

2.10
Регулировка параметров электронного блока управления
-//-

2.11
Проверка и регулировка работы внешних устройств, подключенных к автоматике шлагбаума
-//-

3. Автоматический электропривод ворот

3.1
Акустический и визуальный контроль работы узлов автоматического электропривода
1 раз в 6 месяцев

3.2
Проверка корпуса электропривода и полотна ворот на наличие механических повреждений
-//-

3.3
Промывка Уайт спиритом подвижных элементов механизма и смазка рабочих поверхностей шестерни редуктора и зубчатой рейки силиконовой смазкой
-//-

3.4
Протяжка болтовых и винтовых соединений
-//-

3.5
Проверка работы и регулировка концевых выключателей электропривода в крайних положениях полотна ворот
-//-

3.6
Проверка и регулировка тормозной муфты
-//-

3.7
Проверка утечки смазки из корпуса редуктора и подтяжка креплений редуктора и опор привода
-//-

3.8
Регулировка параметров электронного блока управления
-//-

3.9
Проверка и регулировка работы внешних устройств, подключенных к автоматике шлагбаума
-//-

4.1
Удалить чистой ветошью, смоченной спирто-бензиновой смесью, загрязнение с поверхности кольца контрольного, находящегося в зазоре оптических датчиков попреграждающих планок.
1 раз в 6 месяцев

4.2
Выполнить смазку узлов трения устройства домаслом машинным типа И-20: — четыре втулки на устройстве до(две — на оси вращения толкателя, две — на оси крепления пружин); — отверстия в деталях крепления пружин; — механизма секретности замка механической разблокировки через замочную скважину Не допускать попадания смазки на поверхность кольца контрольного и на ролик!
-//-

4.3
Проверить надежность крепления кабелей в клеммных колодках платы CLB и, при необходимости, подтянуть отверткой винты крепления кабелей.
-//-

4.4
Проверить надежность крепления преграждающих планок и, при необходимости, подтянуть болты крепления преграждающих планок.
-//-

4.5
Проверить надежность крепления стойки турникета к полу и, при необходимости, торцовым ключом подтянуть болты анкеров
-//-

4.6
Проверка работы системы во всех предусмотренных режимах
-//-

Прайс-лист на обслуживание / ремонт автоматических дверей.

* — дополнительно к сумме ремонта (или обслуживания) оплачивается выезд инженера, в соответствии с расценками: 1. в пределах мкад, и м.о. до 20 км от мкад — 2000 рублей. 2. м.о. до 50 км от мкад — 2500 рублей. 3. до 120 км от мкад — 3500 рублей. ** — по результатам диагностики.


Работы
Ед. Изм.
Кол-во
Сумма, руб.*

1.
Разовое ТО автоматической двери
шт.
1
2500

2.
Замена блока управления с настройкой параметров пользователя
шт.
1
2000

3.
Замена приводного ремня
шт.
1
800

4.
Замена мотор-редуктора с регулировкой натяжения приводного ремня
шт.
1
1200

5.
Замена ролика каретки (тележки) привода
шт.
1
300

6.
Замена селектора (переключателя режимов работы) на идентичный без изменения местоположения
шт.
1
1400

7.
Замена переключателя режимов
шт.
1
1800

8.
Замена радара (детектора движения) с последующей настройкой
шт.
1
1550

9.
Замена фотоэлемента безопасности
шт.
1
3000

10.
Замена платы расширения
шт.
1
500

11.
Замена блока питания
шт.
1
700

12.
Настройка параметров блока управления (без перезагрузки)
шт.
1
1200

13.
Настройка параметров блока управления (с перезагрузкой)
шт.
1
1500

14.
Замена натяжного ролика с последующей регулировкой натяжения ремня привода
шт.
1
900

15.
Замена каретки (тележки) подвижной створки
шт.
1
800

16.
Замена оператора (без стоимости доставки)
шт.
1
14500

17.
Замена крышки оператора (без стоимости покраски и доставки)
шт.
1
2200

18.
Диагностика привода автоматической двери
шт.
1
2000

19.
Замена стекла (триплекс) подвижной створки при площади створки до 2 кв.м.
шт.
1
4500

21.
Замена стекла (триплекс) подвижной створки при площади створки более 2 кв.м.
шт.
1
5500

22.
Замена электромеханического замка
шт.
1
1300

23.
Замена механического разблокиратора замка
шт.
1
1700

24.
Ремонт мотор-редуктора привода
шт.
1
**

25.
Ремонт подвижной створки
шт.
1
**

26.
Замена кнопки аварийной остановки (или аварийного открывания двери)
шт.
1
700

27.
Замена аккумуляторной батареи автоматической двери
шт.
1
450

27.
Замена энкодера привода автоматической двери (без стоимости энкодера)
шт.
1
1450

28.
Замена напольной направляющей подвижной створки (без ее стоимости)
шт.
1
1200

Возможно, вам также будет интересно:

  • Doors 800 ошибка калибровки
  • Door bridge отис ошибка
  • Doom ошибка при загрузке
  • Doom eternal ошибка точка входа не найдена
  • Doom eternal ошибка при запуске приложения 0xc000007b

  • Понравилась статья? Поделить с друзьями:
    0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии